Geant4 and Fano cavity test: where are we?

The electron transport algorithm implemented in Geant4 has been recently revised. The modifications concern several physics aspects of the simulation model: the step limitation, the energy loss along a step and the multiple scattering. The Fano cavity setup was used to test these developments. The u...

Descripción completa

Detalles Bibliográficos
Autores principales: Elles, S, Ivanchenko, V N, Maire, M, Urbàn, L
Lenguaje:eng
Publicado: 2008
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1742-6596/102/1/012009
http://cds.cern.ch/record/1178495
_version_ 1780916301190922240
author Elles, S
Ivanchenko, V N
Maire, M
Urbàn, L
author_facet Elles, S
Ivanchenko, V N
Maire, M
Urbàn, L
author_sort Elles, S
collection CERN
description The electron transport algorithm implemented in Geant4 has been recently revised. The modifications concern several physics aspects of the simulation model: the step limitation, the energy loss along a step and the multiple scattering. The Fano cavity setup was used to test these developments. The upgrades increase significantly the accuracy of the electron transport simulation. The ratio of simulated to theoretical dose deposition in the cavity is stable to ~1% while varying several parameters and within ~1.5% of the expected value for water and graphite. Work is underway to identify and resolve the remaining shift.
id cern-1178495
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2008
record_format invenio
spelling cern-11784952022-08-17T13:35:31Zdoi:10.1088/1742-6596/102/1/012009http://cds.cern.ch/record/1178495engElles, SIvanchenko, V NMaire, MUrbàn, LGeant4 and Fano cavity test: where are we?Detectors and Experimental TechniquesThe electron transport algorithm implemented in Geant4 has been recently revised. The modifications concern several physics aspects of the simulation model: the step limitation, the energy loss along a step and the multiple scattering. The Fano cavity setup was used to test these developments. The upgrades increase significantly the accuracy of the electron transport simulation. The ratio of simulated to theoretical dose deposition in the cavity is stable to ~1% while varying several parameters and within ~1.5% of the expected value for water and graphite. Work is underway to identify and resolve the remaining shift.oai:cds.cern.ch:11784952008
spellingShingle Detectors and Experimental Techniques
Elles, S
Ivanchenko, V N
Maire, M
Urbàn, L
Geant4 and Fano cavity test: where are we?
title Geant4 and Fano cavity test: where are we?
title_full Geant4 and Fano cavity test: where are we?
title_fullStr Geant4 and Fano cavity test: where are we?
title_full_unstemmed Geant4 and Fano cavity test: where are we?
title_short Geant4 and Fano cavity test: where are we?
title_sort geant4 and fano cavity test: where are we?
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1742-6596/102/1/012009
http://cds.cern.ch/record/1178495
work_keys_str_mv AT elless geant4andfanocavitytestwherearewe
AT ivanchenkovn geant4andfanocavitytestwherearewe
AT mairem geant4andfanocavitytestwherearewe
AT urbanl geant4andfanocavitytestwherearewe