Fast Wire Scanner Calibration

The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibrat...

Descripción completa

Detalles Bibliográficos
Autores principales: Lokhovitskiy, A, Koopman, J, Guerrero, A
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1183402
_version_ 1780916381547495424
author Lokhovitskiy, A
Koopman, J
Guerrero, A
author_facet Lokhovitskiy, A
Koopman, J
Guerrero, A
author_sort Lokhovitskiy, A
collection CERN
description The fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner parts; automation of the calibration procedure to exclude human errors in data taking, storing and analysis; high precision of the laser positioning; minimization of the total amount of scans and calibration time for each scanner.
id cern-1183402
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-11834022019-09-30T06:29:59Zhttp://cds.cern.ch/record/1183402engLokhovitskiy, AKoopman, JGuerrero, AFast Wire Scanner CalibrationAccelerators and Storage RingsThe fast rotating wire scanners installed in the PS and the PS booster are used for the precise transversal profile measurements in horizontal and vertical planes. The scanners may show large position measurement errors if no special treatment is applied to the acquired data. The aim of the calibration is to obtain a correction algorithm for the systematic position measurement error due to mechanical and electronic offsets. A new calibration system has been developed and introduced at CERN for the scanners implementing position feedback control. The calibration method is based on a substitution of a particle beam by a laser one where the laser beam position is well known. According to the previous experience the following crucial requirements to the system have been taking into consideration: heavy and mechanically stable design of the calibration bench to reduce mechanical oscillations of scanner parts; automation of the calibration procedure to exclude human errors in data taking, storing and analysis; high precision of the laser positioning; minimization of the total amount of scans and calibration time for each scanner.CERN-BE-2009-020oai:cds.cern.ch:11834022009-05-01
spellingShingle Accelerators and Storage Rings
Lokhovitskiy, A
Koopman, J
Guerrero, A
Fast Wire Scanner Calibration
title Fast Wire Scanner Calibration
title_full Fast Wire Scanner Calibration
title_fullStr Fast Wire Scanner Calibration
title_full_unstemmed Fast Wire Scanner Calibration
title_short Fast Wire Scanner Calibration
title_sort fast wire scanner calibration
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1183402
work_keys_str_mv AT lokhovitskiya fastwirescannercalibration
AT koopmanj fastwirescannercalibration
AT guerreroa fastwirescannercalibration