Cargando…
A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements
A real-time algorithm of data reduction, based on the combination a two lossy techniques specifically optimized for high-rate magnetic measurements in two domains (e.g. time and space), is proposed. The first technique exploits an adaptive sampling rule based on the power estimation of the flux incr...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/0957-0233/21/3/035103 http://cds.cern.ch/record/1186675 |
_version_ | 1780916471502733312 |
---|---|
author | Arpaia, P Buzio, M Inglese, V |
author_facet | Arpaia, P Buzio, M Inglese, V |
author_sort | Arpaia, P |
collection | CERN |
description | A real-time algorithm of data reduction, based on the combination a two lossy techniques specifically optimized for high-rate magnetic measurements in two domains (e.g. time and space), is proposed. The first technique exploits an adaptive sampling rule based on the power estimation of the flux increments in order to optimize the information to be gathered for magnetic field analysis in real time. The tracking condition is defined by the target noise level in the Nyquist band required by post-processing procedure of magnetic analysis. The second technique uses a data reduction algorithm in order to improve the compression ratio while preserving the consistency of the measured signal. The allowed loss is set equal to the random noise level in the signal in order to force the loss and the noise to cancel rather than to add, by improving the signal-to-noise ratio. Numerical analysis and experimental results of on-field performance characterization and validation for two case studies of magnetic measurement systems for testing superconducting and resistive magnets of the Large Hadron Collider at the European Organization for Nuclear Research (CERN) are reported. |
id | cern-1186675 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2009 |
record_format | invenio |
spelling | cern-11866752019-09-30T06:29:59Zdoi:10.1088/0957-0233/21/3/035103http://cds.cern.ch/record/1186675engArpaia, PBuzio, MInglese, VA two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurementsAccelerators and Storage RingsA real-time algorithm of data reduction, based on the combination a two lossy techniques specifically optimized for high-rate magnetic measurements in two domains (e.g. time and space), is proposed. The first technique exploits an adaptive sampling rule based on the power estimation of the flux increments in order to optimize the information to be gathered for magnetic field analysis in real time. The tracking condition is defined by the target noise level in the Nyquist band required by post-processing procedure of magnetic analysis. The second technique uses a data reduction algorithm in order to improve the compression ratio while preserving the consistency of the measured signal. The allowed loss is set equal to the random noise level in the signal in order to force the loss and the noise to cancel rather than to add, by improving the signal-to-noise ratio. Numerical analysis and experimental results of on-field performance characterization and validation for two case studies of magnetic measurement systems for testing superconducting and resistive magnets of the Large Hadron Collider at the European Organization for Nuclear Research (CERN) are reported.CERN-TE-2009-001oai:cds.cern.ch:11866752009-06-26 |
spellingShingle | Accelerators and Storage Rings Arpaia, P Buzio, M Inglese, V A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements |
title | A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements |
title_full | A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements |
title_fullStr | A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements |
title_full_unstemmed | A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements |
title_short | A two-domain real-time algorithm for optimal data reduction: A case study on accelerator magnet measurements |
title_sort | two-domain real-time algorithm for optimal data reduction: a case study on accelerator magnet measurements |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.1088/0957-0233/21/3/035103 http://cds.cern.ch/record/1186675 |
work_keys_str_mv | AT arpaiap atwodomainrealtimealgorithmforoptimaldatareductionacasestudyonacceleratormagnetmeasurements AT buziom atwodomainrealtimealgorithmforoptimaldatareductionacasestudyonacceleratormagnetmeasurements AT inglesev atwodomainrealtimealgorithmforoptimaldatareductionacasestudyonacceleratormagnetmeasurements AT arpaiap twodomainrealtimealgorithmforoptimaldatareductionacasestudyonacceleratormagnetmeasurements AT buziom twodomainrealtimealgorithmforoptimaldatareductionacasestudyonacceleratormagnetmeasurements AT inglesev twodomainrealtimealgorithmforoptimaldatareductionacasestudyonacceleratormagnetmeasurements |