Cargando…

Orthogonal Coupling in Cavity BPM with Slots

XFELs require high precision orbit control in their long undulator sections. Due to the pulsed operation of drive linacs the high precision has to be reached by single bunch measurements. So far only cavity BPMs achieve the required performance and will be used at the European XFEL, one between each...

Descripción completa

Detalles Bibliográficos
Autores principales: Lipka, D, Nölle, D, Siemens, M, Vilcins, S, Caspers, Friedhelm, Stadler, M, Treyer, DM, Maesaka, H, Shintake, T
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1187848
_version_ 1780916499670630400
author Lipka, D
Nölle, D
Siemens, M
Vilcins, S
Caspers, Friedhelm
Stadler, M
Treyer, DM
Maesaka, H
Shintake, T
author_facet Lipka, D
Nölle, D
Siemens, M
Vilcins, S
Caspers, Friedhelm
Stadler, M
Treyer, DM
Maesaka, H
Shintake, T
author_sort Lipka, D
collection CERN
description XFELs require high precision orbit control in their long undulator sections. Due to the pulsed operation of drive linacs the high precision has to be reached by single bunch measurements. So far only cavity BPMs achieve the required performance and will be used at the European XFEL, one between each of the up to 116 undulators. Coupling between the orthogonal planes limits the performance of beam position measurements. A first prototype build at DESY shows a coupling between orthogonal planes of about -20 dB, but the requirement is lower than -40 dB (1%). The next generation cavity BPM was build with tighter tolerances and mechanical changes, the orthogonal coupling is measured to be lower than -43 dB. This report discusses the various observations, measurements and improvements which were done.
id cern-1187848
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-11878482019-09-30T06:29:59Zhttp://cds.cern.ch/record/1187848engLipka, DNölle, DSiemens, MVilcins, SCaspers, FriedhelmStadler, MTreyer, DMMaesaka, HShintake, TOrthogonal Coupling in Cavity BPM with SlotsAccelerators and Storage RingsXFELs require high precision orbit control in their long undulator sections. Due to the pulsed operation of drive linacs the high precision has to be reached by single bunch measurements. So far only cavity BPMs achieve the required performance and will be used at the European XFEL, one between each of the up to 116 undulators. Coupling between the orthogonal planes limits the performance of beam position measurements. A first prototype build at DESY shows a coupling between orthogonal planes of about -20 dB, but the requirement is lower than -40 dB (1%). The next generation cavity BPM was build with tighter tolerances and mechanical changes, the orthogonal coupling is measured to be lower than -43 dB. This report discusses the various observations, measurements and improvements which were done.CERN-BE-2009-034oai:cds.cern.ch:11878482009-05-25
spellingShingle Accelerators and Storage Rings
Lipka, D
Nölle, D
Siemens, M
Vilcins, S
Caspers, Friedhelm
Stadler, M
Treyer, DM
Maesaka, H
Shintake, T
Orthogonal Coupling in Cavity BPM with Slots
title Orthogonal Coupling in Cavity BPM with Slots
title_full Orthogonal Coupling in Cavity BPM with Slots
title_fullStr Orthogonal Coupling in Cavity BPM with Slots
title_full_unstemmed Orthogonal Coupling in Cavity BPM with Slots
title_short Orthogonal Coupling in Cavity BPM with Slots
title_sort orthogonal coupling in cavity bpm with slots
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1187848
work_keys_str_mv AT lipkad orthogonalcouplingincavitybpmwithslots
AT nolled orthogonalcouplingincavitybpmwithslots
AT siemensm orthogonalcouplingincavitybpmwithslots
AT vilcinss orthogonalcouplingincavitybpmwithslots
AT caspersfriedhelm orthogonalcouplingincavitybpmwithslots
AT stadlerm orthogonalcouplingincavitybpmwithslots
AT treyerdm orthogonalcouplingincavitybpmwithslots
AT maesakah orthogonalcouplingincavitybpmwithslots
AT shintaket orthogonalcouplingincavitybpmwithslots