Test Results from the PF Conductor Insert Coil and Implications for the ITER PF System

In this paper we report the main test results obtained on the Poloidal Field Conductor Insert coil (PFI) for the International Thermonuclear Experimental Reactor (ITER), built jointly by the EU and RF ITER parties, recently installed and tested in the CS Model Coil facility, at JAEA-Naka. During the...

Descripción completa

Detalles Bibliográficos
Autores principales: Bessette, D, Bottura, L, Devred, A, Mitchell, N, Okuno, K, Nunoya, Y, Sborchia, C, Takahashi, Y, Verweij, A, Vostner, A, Zanino, R, Zapretilina, E
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2009.2017922
http://cds.cern.ch/record/1192838
Descripción
Sumario:In this paper we report the main test results obtained on the Poloidal Field Conductor Insert coil (PFI) for the International Thermonuclear Experimental Reactor (ITER), built jointly by the EU and RF ITER parties, recently installed and tested in the CS Model Coil facility, at JAEA-Naka. During the test we (a) verified the DC and AC operating margin of the NbTi Cable-in-Conduit Conductor in conditions representative of the operation of the ITER PF coils, (b) measured the intermediate conductor joint resistance, margin and loss, and (c) measured the AC loss of the conductor and its changes once subjected to a significant number of Lorentz force cycles. We compare the results obtained to expectations from strand and cable characterization, which were studied extensively earlier. We finally discuss the implications for the ITER PF system.