Cargando…

Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb

The Ring Imaging CHerenkov, RICH, detector at LHCb is now readout by Hybrid Photon Detectors. In view of its upgrade a possible option is the adoption of the flat panel Photon Multipliers Tubes, PMT. An important issue for the good determination of the rings produced in the sensitive media is a negl...

Descripción completa

Detalles Bibliográficos
Autores principales: Arnaboldi, C, Artuso, M, Calvi, M, Fanchini, E, Gotti, C, Maino, M, Matteuzzi, C, Perego, D L, Pessina, G, Wang, J C
Lenguaje:eng
Publicado: 2009
Acceso en línea:http://cds.cern.ch/record/1217158
_version_ 1780918154112794624
author Arnaboldi, C
Artuso, M
Calvi, M
Fanchini, E
Gotti, C
Maino, M
Matteuzzi, C
Perego, D L
Pessina, G
Wang, J C
author_facet Arnaboldi, C
Artuso, M
Calvi, M
Fanchini, E
Gotti, C
Maino, M
Matteuzzi, C
Perego, D L
Pessina, G
Wang, J C
author_sort Arnaboldi, C
collection CERN
description The Ring Imaging CHerenkov, RICH, detector at LHCb is now readout by Hybrid Photon Detectors. In view of its upgrade a possible option is the adoption of the flat panel Photon Multipliers Tubes, PMT. An important issue for the good determination of the rings produced in the sensitive media is a negligible level of cross talk. We have experimentally studied the cross talk from the 64x64 pixels of the H9500 PMT from Hamamatsu. Results have shown that at the single photon signal level, as expected at LHCb, the statistics applied to the small number of electrons generated at the first dynode of the PMT chain leads to a cross talk mechanism that must be interpreted in term of the percentage of the number of induced signals rather than on the amplitude of the induced signals. The threshold to suppress cross talk must be increased to a significant fraction of the single photon signal for the worst case. The number of electrons generated at the first dynode is proportional to the biasing voltage. Measurements have shown that the suppressing threshold can be lowered acting on this latter parameter.
id cern-1217158
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-12171582019-09-30T06:29:59Zhttp://cds.cern.ch/record/1217158engArnaboldi, CArtuso, MCalvi, MFanchini, EGotti, CMaino, MMatteuzzi, CPerego, D LPessina, GWang, J CCross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCbThe Ring Imaging CHerenkov, RICH, detector at LHCb is now readout by Hybrid Photon Detectors. In view of its upgrade a possible option is the adoption of the flat panel Photon Multipliers Tubes, PMT. An important issue for the good determination of the rings produced in the sensitive media is a negligible level of cross talk. We have experimentally studied the cross talk from the 64x64 pixels of the H9500 PMT from Hamamatsu. Results have shown that at the single photon signal level, as expected at LHCb, the statistics applied to the small number of electrons generated at the first dynode of the PMT chain leads to a cross talk mechanism that must be interpreted in term of the percentage of the number of induced signals rather than on the amplitude of the induced signals. The threshold to suppress cross talk must be increased to a significant fraction of the single photon signal for the worst case. The number of electrons generated at the first dynode is proportional to the biasing voltage. Measurements have shown that the suppressing threshold can be lowered acting on this latter parameter.Poster-2009-137oai:cds.cern.ch:12171582009-10-25
spellingShingle Arnaboldi, C
Artuso, M
Calvi, M
Fanchini, E
Gotti, C
Maino, M
Matteuzzi, C
Perego, D L
Pessina, G
Wang, J C
Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb
title Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb
title_full Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb
title_fullStr Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb
title_full_unstemmed Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb
title_short Cross Talk Study to the Single Photon Response of a Flat Panel PMT for the RICH Upgrade at LHCb
title_sort cross talk study to the single photon response of a flat panel pmt for the rich upgrade at lhcb
url http://cds.cern.ch/record/1217158
work_keys_str_mv AT arnaboldic crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT artusom crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT calvim crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT fanchinie crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT gottic crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT mainom crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT matteuzzic crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT peregodl crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT pessinag crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb
AT wangjc crosstalkstudytothesinglephotonresponseofaflatpanelpmtfortherichupgradeatlhcb