Cargando…

Resistance of LHC main bus bar splices at room temperature and at 77.4 K

As part of the quality control the resistance of newly produced LHC main bus bar splices is now routinely measured at room temperature (RT) in order to conclude on the electrical continuity of the bus bar stabiliser across the splice under operating conditions. In this note we present splice resista...

Descripción completa

Detalles Bibliográficos
Autores principales: Heck, S, Dufay-Chanat, L, Scheuerlein, Chr
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1225908

Ejemplares similares