Cargando…

Transverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4

This report evaluates the applicability of the Three-Monitor-Method to determine the transverse emittance of the CERN Linac4 160 MeV H- -beam. The Three-Monitor-Method is a linear formalism allowing to calculate transverse emittance values from beam size measurements at three different positions alo...

Descripción completa

Detalles Bibliográficos
Autores principales: Hanke, K, Hermanns, T, Mikulec, B
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1226292
_version_ 1780918419760087040
author Hanke, K
Hermanns, T
Mikulec, B
author_facet Hanke, K
Hermanns, T
Mikulec, B
author_sort Hanke, K
collection CERN
description This report evaluates the applicability of the Three-Monitor-Method to determine the transverse emittance of the CERN Linac4 160 MeV H- -beam. The Three-Monitor-Method is a linear formalism allowing to calculate transverse emittance values from beam size measurements at three different positions along a beam line, assuming that the transfer matrix elements between these locations are known. It is planned to build two of these measurement systems, which should operate from 2013/14 immediately behind the exit of the linear accelerator in the dump line and close to the end of the transfer line to the PS Booster synchrotron in the LBE line. At first, the mathematical formalism and the simulation tools are briefly introduced. Then, the method is applied for both measurement lines. Results on measurement precisions and systematic errors are presented. Final conclusions are drawn at the end, and a summary of the equipment to be installed or modified will be given.
id cern-1226292
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-12262922019-09-30T06:29:59Zhttp://cds.cern.ch/record/1226292engHanke, KHermanns, TMikulec, BTransverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4Accelerators and Storage RingsThis report evaluates the applicability of the Three-Monitor-Method to determine the transverse emittance of the CERN Linac4 160 MeV H- -beam. The Three-Monitor-Method is a linear formalism allowing to calculate transverse emittance values from beam size measurements at three different positions along a beam line, assuming that the transfer matrix elements between these locations are known. It is planned to build two of these measurement systems, which should operate from 2013/14 immediately behind the exit of the linear accelerator in the dump line and close to the end of the transfer line to the PS Booster synchrotron in the LBE line. At first, the mathematical formalism and the simulation tools are briefly introduced. Then, the method is applied for both measurement lines. Results on measurement precisions and systematic errors are presented. Final conclusions are drawn at the end, and a summary of the equipment to be installed or modified will be given.sLHC-PROJECT-Report-0029CERN-sLHC-PROJECT-Report-0029oai:cds.cern.ch:12262922009-12-02
spellingShingle Accelerators and Storage Rings
Hanke, K
Hermanns, T
Mikulec, B
Transverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4
title Transverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4
title_full Transverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4
title_fullStr Transverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4
title_full_unstemmed Transverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4
title_short Transverse Emittance Measurement with the Three-Monitor-Method at the CERN Linac4
title_sort transverse emittance measurement with the three-monitor-method at the cern linac4
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1226292
work_keys_str_mv AT hankek transverseemittancemeasurementwiththethreemonitormethodatthecernlinac4
AT hermannst transverseemittancemeasurementwiththethreemonitormethodatthecernlinac4
AT mikulecb transverseemittancemeasurementwiththethreemonitormethodatthecernlinac4