Cargando…
The Argon Dark Matter Experiment
The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nucleus, producing nuclear recoils. These events will be discerned by their light to charge ratio, as well as the time structure of the scintilla...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1742-6596/203/1/012024 http://cds.cern.ch/record/1229122 |
_version_ | 1780918454678716416 |
---|---|
author | Regenfus, Christian |
author_facet | Regenfus, Christian |
author_sort | Regenfus, Christian |
collection | CERN |
description | The ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nucleus, producing nuclear recoils. These events will be discerned by their light to charge ratio, as well as the time structure of the scintillation light. The experiment is presently under construction and commissioning on surface at CERN. Cryogenic operation and light detection performance was recently confirmed in a test run of the full 1 ton liquid argon target under purely calorimetric operation and with a prototype light readout system. This note describes the experimental concept, the main detector components and presents some first results. |
id | cern-1229122 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2009 |
record_format | invenio |
spelling | cern-12291222022-08-17T13:37:30Zdoi:10.1088/1742-6596/203/1/012024http://cds.cern.ch/record/1229122engRegenfus, ChristianThe Argon Dark Matter ExperimentDetectors and Experimental TechniquesThe ArDM experiment, a 1 ton liquid argon TPC/Calorimeter, is designed for the detection of dark matter particles which can scatter off the spinless argon nucleus, producing nuclear recoils. These events will be discerned by their light to charge ratio, as well as the time structure of the scintillation light. The experiment is presently under construction and commissioning on surface at CERN. Cryogenic operation and light detection performance was recently confirmed in a test run of the full 1 ton liquid argon target under purely calorimetric operation and with a prototype light readout system. This note describes the experimental concept, the main detector components and presents some first results.arXiv:0912.2962oai:cds.cern.ch:12291222009-12-16 |
spellingShingle | Detectors and Experimental Techniques Regenfus, Christian The Argon Dark Matter Experiment |
title | The Argon Dark Matter Experiment |
title_full | The Argon Dark Matter Experiment |
title_fullStr | The Argon Dark Matter Experiment |
title_full_unstemmed | The Argon Dark Matter Experiment |
title_short | The Argon Dark Matter Experiment |
title_sort | argon dark matter experiment |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1742-6596/203/1/012024 http://cds.cern.ch/record/1229122 |
work_keys_str_mv | AT regenfuschristian theargondarkmatterexperiment AT regenfuschristian argondarkmatterexperiment |