Cargando…

In-situ performance of the CMS Preshower Detector

The CMS Preshower detector, based on silicon strip sensors, was installed on the two endcaps of CMS in March/April 2009. First commissioning showed that of the 137216 electronics channels almost all (>99.9%) are fully operational. This report summarizes the electronics integration (ondetector) an...

Descripción completa

Detalles Bibliográficos
Autor principal: Bialas, W
Lenguaje:eng
Publicado: CERN 2009
Materias:
Acceso en línea:https://dx.doi.org/10.5170/CERN-2009-006.96
http://cds.cern.ch/record/1234877
Descripción
Sumario:The CMS Preshower detector, based on silicon strip sensors, was installed on the two endcaps of CMS in March/April 2009. First commissioning showed that of the 137216 electronics channels almost all (>99.9%) are fully operational. This report summarizes the electronics integration (ondetector) and in-situ performance in terms of noise (including common-mode pickup). First observations of in-situ cosmicrays during CMS summer CRAFT program are presented.