Cargando…

Temperature Induced Degradation of Nb Ti/Cu Composite Superconductors

The degradation mechanisms of state-of-the-art Nb-Ti/Cu superconductors are described, based on in-situ synchrotron X-ray diffraction measurements during heat treatment. A quantitative description of the Nb-Ti/Cu degradation in terms of critical current density, Cu stabiliser resistivity and mechani...

Descripción completa

Detalles Bibliográficos
Autores principales: Scheuerlein, C, Pong, I, Senatore, C, Di Michiel, M, Thilly, L, Gerardin, A, Reluner, B, Oberli, L, Willering, G, Bottura, L
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1235166
_version_ 1780918542910095360
author Scheuerlein, C
Pong, I
Senatore, C
Di Michiel, M
Thilly, L
Gerardin, A
Reluner, B
Oberli, L
Willering, G
Bottura, L
author_facet Scheuerlein, C
Pong, I
Senatore, C
Di Michiel, M
Thilly, L
Gerardin, A
Reluner, B
Oberli, L
Willering, G
Bottura, L
author_sort Scheuerlein, C
collection CERN
description The degradation mechanisms of state-of-the-art Nb-Ti/Cu superconductors are described, based on in-situ synchrotron X-ray diffraction measurements during heat treatment. A quantitative description of the Nb-Ti/Cu degradation in terms of critical current density, Cu stabiliser resistivity and mechanical composite strength is presented. In an applied magnetic field a significant critical current degradation is already observed after a 5-minute 400 °C heat treatment, due to variations of a-Ti precipitate size and distribution within the Nb-Ti alloy filaments. A strong degradation of the strand mechanical properties is observed after several minutes heating above 550 °C, which is also the temperature at which the formation of Cu Ti intermetallic phases is detected. Several minutes heating at 250 °C are sufficient to increase the RRR of the strongly cold work strands inside a Rutherford type cable from about 80 to about 240. Heating for several minutes at 400 °C does not cause a significant conductor degradation in self-field and, thus, leaves enough temperature margin for the electrical interconnection of Nb-Ti/Cu conductors with common low temperature solders.
id cern-1235166
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-12351662019-09-30T06:29:59Zhttp://cds.cern.ch/record/1235166engScheuerlein, CPong, ISenatore, CDi Michiel, MThilly, LGerardin, AReluner, BOberli, LWillering, GBottura, LTemperature Induced Degradation of Nb Ti/Cu Composite SuperconductorsAccelerators and Storage RingsThe degradation mechanisms of state-of-the-art Nb-Ti/Cu superconductors are described, based on in-situ synchrotron X-ray diffraction measurements during heat treatment. A quantitative description of the Nb-Ti/Cu degradation in terms of critical current density, Cu stabiliser resistivity and mechanical composite strength is presented. In an applied magnetic field a significant critical current degradation is already observed after a 5-minute 400 °C heat treatment, due to variations of a-Ti precipitate size and distribution within the Nb-Ti alloy filaments. A strong degradation of the strand mechanical properties is observed after several minutes heating above 550 °C, which is also the temperature at which the formation of Cu Ti intermetallic phases is detected. Several minutes heating at 250 °C are sufficient to increase the RRR of the strongly cold work strands inside a Rutherford type cable from about 80 to about 240. Heating for several minutes at 400 °C does not cause a significant conductor degradation in self-field and, thus, leaves enough temperature margin for the electrical interconnection of Nb-Ti/Cu conductors with common low temperature solders.CERN-ATS-2010-004oai:cds.cern.ch:12351662009-11-13
spellingShingle Accelerators and Storage Rings
Scheuerlein, C
Pong, I
Senatore, C
Di Michiel, M
Thilly, L
Gerardin, A
Reluner, B
Oberli, L
Willering, G
Bottura, L
Temperature Induced Degradation of Nb Ti/Cu Composite Superconductors
title Temperature Induced Degradation of Nb Ti/Cu Composite Superconductors
title_full Temperature Induced Degradation of Nb Ti/Cu Composite Superconductors
title_fullStr Temperature Induced Degradation of Nb Ti/Cu Composite Superconductors
title_full_unstemmed Temperature Induced Degradation of Nb Ti/Cu Composite Superconductors
title_short Temperature Induced Degradation of Nb Ti/Cu Composite Superconductors
title_sort temperature induced degradation of nb ti/cu composite superconductors
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1235166
work_keys_str_mv AT scheuerleinc temperatureinduceddegradationofnbticucompositesuperconductors
AT pongi temperatureinduceddegradationofnbticucompositesuperconductors
AT senatorec temperatureinduceddegradationofnbticucompositesuperconductors
AT dimichielm temperatureinduceddegradationofnbticucompositesuperconductors
AT thillyl temperatureinduceddegradationofnbticucompositesuperconductors
AT gerardina temperatureinduceddegradationofnbticucompositesuperconductors
AT relunerb temperatureinduceddegradationofnbticucompositesuperconductors
AT oberlil temperatureinduceddegradationofnbticucompositesuperconductors
AT willeringg temperatureinduceddegradationofnbticucompositesuperconductors
AT bottural temperatureinduceddegradationofnbticucompositesuperconductors