A low mass pixel detector upgrade for CMS

The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced until 2015. The detector performance will be degraded for tw...

Descripción completa

Detalles Bibliográficos
Autor principal: Kastli, H.C.A
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.22323/1.098.0033
http://cds.cern.ch/record/1235240
_version_ 1780918545313431552
author Kastli, H.C.A
author_facet Kastli, H.C.A
author_sort Kastli, H.C.A
collection CERN
description The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced until 2015. The detector performance will be degraded for two reasons: radiation damage of the innermost layers and the planned increase of the LHC peak luminosity by a factor of 2-3. Based on the experience in planning, constructing and commissioning of the present pixel detector, we intend to upgrade the whole pixel detector in 2015. The main focus is on lowering the material budget and adding more tracking points. We will present the design of a new low mass pixel system consisting of 4 barrel layers and 3 end cap disks on each side. The design comprises of thin detector modules and a lightweight mechanical support structure using CO2 cooling. In addition, large efforts have been made to move material from the services out of the tracking region.
id cern-1235240
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-12352402023-03-15T19:11:52Zdoi:10.22323/1.098.0033http://cds.cern.ch/record/1235240engKastli, H.C.AA low mass pixel detector upgrade for CMSDetectors and Experimental TechniquesThe CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced until 2015. The detector performance will be degraded for two reasons: radiation damage of the innermost layers and the planned increase of the LHC peak luminosity by a factor of 2-3. Based on the experience in planning, constructing and commissioning of the present pixel detector, we intend to upgrade the whole pixel detector in 2015. The main focus is on lowering the material budget and adding more tracking points. We will present the design of a new low mass pixel system consisting of 4 barrel layers and 3 end cap disks on each side. The design comprises of thin detector modules and a lightweight mechanical support structure using CO2 cooling. In addition, large efforts have been made to move material from the services out of the tracking region.The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced until 2015. The detector performance will be degraded for two reasons: radiation damage of the innermost layers and the planned increase of the LHC peak luminosity by a factor of 2-3. Based on the experience in planning, constructing and commissioning of the present pixel detector, we intend to upgrade the whole pixel detector in 2015. The main focus is on lowering the material budget and adding more tracking points. We will present the design of a new low mass pixel system consisting of 4 barrel layers and 3 end cap disks on each side. The design comprises of thin detector modules and a lightweight mechanical support structure using CO2 cooling. In addition, large efforts have been made to move material from the services out of the tracking region.arXiv:1001.3933oai:cds.cern.ch:12352402010-01-25
spellingShingle Detectors and Experimental Techniques
Kastli, H.C.A
A low mass pixel detector upgrade for CMS
title A low mass pixel detector upgrade for CMS
title_full A low mass pixel detector upgrade for CMS
title_fullStr A low mass pixel detector upgrade for CMS
title_full_unstemmed A low mass pixel detector upgrade for CMS
title_short A low mass pixel detector upgrade for CMS
title_sort low mass pixel detector upgrade for cms
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.22323/1.098.0033
http://cds.cern.ch/record/1235240
work_keys_str_mv AT kastlihca alowmasspixeldetectorupgradeforcms
AT kastlihca lowmasspixeldetectorupgradeforcms