Cargando…
Novel Charge Sensitive Amplifier Design Methodology suitable for Large Detector Capacitance Applications
Current mode charge sensitive amplifier (CSA) topology and related methodology for use as pre-amplification block in radiation detection read out front end IC systems is proposed1. It is based on the use of a suitably configured current conveyor topology providing advantageous noise performance char...
Autores principales: | Thomas Noulis a, Stylianos Siskos a, Gerard Sarrabayrouse b,c and, Laurent Bary b,c |
---|---|