Cargando…

GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES

The demanding nanometre transverse beam sizes and emittances in future linear accelerators result in stringent alignment and nanometre vibration stability requirements. For more than two decades, ground vibration measurements were made by different teams for feasibility studies of linear accelerator...

Descripción completa

Detalles Bibliográficos
Autores principales: Artoos, K, Capatina, O, Collette, C, Guinchard, M, Hauviller, C, Sylte, M, Bolzon, B, Jeremie, A
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1239667
_version_ 1780918828052512768
author Artoos, K
Capatina, O
Collette, C
Guinchard, M
Hauviller, C
Sylte, M
Bolzon, B
Jeremie, A
author_facet Artoos, K
Capatina, O
Collette, C
Guinchard, M
Hauviller, C
Sylte, M
Bolzon, B
Jeremie, A
author_sort Artoos, K
collection CERN
description The demanding nanometre transverse beam sizes and emittances in future linear accelerators result in stringent alignment and nanometre vibration stability requirements. For more than two decades, ground vibration measurements were made by different teams for feasibility studies of linear accelerators. Recent measurements were performed in the LHC tunnel and at different CERN sites on the surface. The devices to measure nanometre sized vibrations, the analysis techniques and the results are critically discussed and compared with former measurement campaigns. The implication of the measured integrated R.M.S. displacements and coherence length for the CLIC stabilization system are mentioned.
format info:eu-repo/semantics/article
id cern-1239667
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-12396672019-09-30T06:29:59Z http://cds.cern.ch/record/1239667 eng Artoos, K Capatina, O Collette, C Guinchard, M Hauviller, C Sylte, M Bolzon, B Jeremie, A GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators The demanding nanometre transverse beam sizes and emittances in future linear accelerators result in stringent alignment and nanometre vibration stability requirements. For more than two decades, ground vibration measurements were made by different teams for feasibility studies of linear accelerators. Recent measurements were performed in the LHC tunnel and at different CERN sites on the surface. The devices to measure nanometre sized vibrations, the analysis techniques and the results are critically discussed and compared with former measurement campaigns. The implication of the measured integrated R.M.S. displacements and coherence length for the CLIC stabilization system are mentioned. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1239667 2009
spellingShingle Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
Artoos, K
Capatina, O
Collette, C
Guinchard, M
Hauviller, C
Sylte, M
Bolzon, B
Jeremie, A
GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES
title GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES
title_full GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES
title_fullStr GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES
title_full_unstemmed GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES
title_short GROUND VIBRATION AND COHERENCE LENGTH MEASUREMENTS FOR THE CLIC NANO-STABILIZATION STUDIES
title_sort ground vibration and coherence length measurements for the clic nano-stabilization studies
topic Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
url http://cds.cern.ch/record/1239667
http://cds.cern.ch/record/1239667
work_keys_str_mv AT artoosk groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies
AT capatinao groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies
AT collettec groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies
AT guinchardm groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies
AT hauvillerc groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies
AT syltem groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies
AT bolzonb groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies
AT jeremiea groundvibrationandcoherencelengthmeasurementsfortheclicnanostabilizationstudies