Cargando…
Propagation error simulations concerning the CLIC active prealignment
The CLIC1 components will have to be prealigned within a thirty times more demanding tolerance than the existing CERNmachines. It is a technical challenge and a key issue for the CLIC feasibility. Simulations have been undertaken concerning the propagation error due to the measurement uncertainties...
Autores principales: | , , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1239668 |
_version_ | 1780918828268519424 |
---|---|
author | Touzé, T Mainaud-Durand, H Missiaen, D |
author_facet | Touzé, T Mainaud-Durand, H Missiaen, D |
author_sort | Touzé, T |
collection | CERN |
description | The CLIC1 components will have to be prealigned within a thirty times more demanding tolerance than the existing CERNmachines. It is a technical challenge and a key issue for the CLIC feasibility. Simulations have been undertaken concerning the propagation error due to the measurement uncertainties of the prealignment systems. The uncertainties of measurement, taken as hypothesis for the simulations, are based on the data obtained on several dedicated facilities. This paper introduces the simulations and the latest results obtained, as well as the facilities. |
format | info:eu-repo/semantics/article |
id | cern-1239668 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2009 |
record_format | invenio |
spelling | cern-12396682023-07-20T15:01:46Z http://cds.cern.ch/record/1239668 eng Touzé, T Mainaud-Durand, H Missiaen, D Propagation error simulations concerning the CLIC active prealignment Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators The CLIC1 components will have to be prealigned within a thirty times more demanding tolerance than the existing CERNmachines. It is a technical challenge and a key issue for the CLIC feasibility. Simulations have been undertaken concerning the propagation error due to the measurement uncertainties of the prealignment systems. The uncertainties of measurement, taken as hypothesis for the simulations, are based on the data obtained on several dedicated facilities. This paper introduces the simulations and the latest results obtained, as well as the facilities. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1239668 2009 |
spellingShingle | Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators Touzé, T Mainaud-Durand, H Missiaen, D Propagation error simulations concerning the CLIC active prealignment |
title | Propagation error simulations concerning the CLIC active prealignment |
title_full | Propagation error simulations concerning the CLIC active prealignment |
title_fullStr | Propagation error simulations concerning the CLIC active prealignment |
title_full_unstemmed | Propagation error simulations concerning the CLIC active prealignment |
title_short | Propagation error simulations concerning the CLIC active prealignment |
title_sort | propagation error simulations concerning the clic active prealignment |
topic | Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators |
url | http://cds.cern.ch/record/1239668 http://cds.cern.ch/record/1239668 |
work_keys_str_mv | AT touzet propagationerrorsimulationsconcerningtheclicactiveprealignment AT mainauddurandh propagationerrorsimulationsconcerningtheclicactiveprealignment AT missiaend propagationerrorsimulationsconcerningtheclicactiveprealignment |