Propagation error simulations concerning the CLIC active prealignment

The CLIC1 components will have to be prealigned within a thirty times more demanding tolerance than the existing CERNmachines. It is a technical challenge and a key issue for the CLIC feasibility. Simulations have been undertaken concerning the propagation error due to the measurement uncertainties...

Descripción completa

Detalles Bibliográficos
Autores principales: Touzé, T, Mainaud-Durand, H, Missiaen, D
Formato: info:eu-repo/semantics/article
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1239668
_version_ 1780918828268519424
author Touzé, T
Mainaud-Durand, H
Missiaen, D
author_facet Touzé, T
Mainaud-Durand, H
Missiaen, D
author_sort Touzé, T
collection CERN
description The CLIC1 components will have to be prealigned within a thirty times more demanding tolerance than the existing CERNmachines. It is a technical challenge and a key issue for the CLIC feasibility. Simulations have been undertaken concerning the propagation error due to the measurement uncertainties of the prealignment systems. The uncertainties of measurement, taken as hypothesis for the simulations, are based on the data obtained on several dedicated facilities. This paper introduces the simulations and the latest results obtained, as well as the facilities.
format info:eu-repo/semantics/article
id cern-1239668
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-12396682023-07-20T15:01:46Z http://cds.cern.ch/record/1239668 eng Touzé, T Mainaud-Durand, H Missiaen, D Propagation error simulations concerning the CLIC active prealignment Accelerators and Storage Rings 9: Technology for normal conducting higher energy linear accelerators The CLIC1 components will have to be prealigned within a thirty times more demanding tolerance than the existing CERNmachines. It is a technical challenge and a key issue for the CLIC feasibility. Simulations have been undertaken concerning the propagation error due to the measurement uncertainties of the prealignment systems. The uncertainties of measurement, taken as hypothesis for the simulations, are based on the data obtained on several dedicated facilities. This paper introduces the simulations and the latest results obtained, as well as the facilities. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1239668 2009
spellingShingle Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
Touzé, T
Mainaud-Durand, H
Missiaen, D
Propagation error simulations concerning the CLIC active prealignment
title Propagation error simulations concerning the CLIC active prealignment
title_full Propagation error simulations concerning the CLIC active prealignment
title_fullStr Propagation error simulations concerning the CLIC active prealignment
title_full_unstemmed Propagation error simulations concerning the CLIC active prealignment
title_short Propagation error simulations concerning the CLIC active prealignment
title_sort propagation error simulations concerning the clic active prealignment
topic Accelerators and Storage Rings
9: Technology for normal conducting higher energy linear accelerators
url http://cds.cern.ch/record/1239668
http://cds.cern.ch/record/1239668
work_keys_str_mv AT touzet propagationerrorsimulationsconcerningtheclicactiveprealignment
AT mainauddurandh propagationerrorsimulationsconcerningtheclicactiveprealignment
AT missiaend propagationerrorsimulationsconcerningtheclicactiveprealignment