Cargando…

The robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS Preshower

There is no strong DC link between the individual modules, "ladders" of the Preshower. Non-negligible DC-offsets may occur between the grounds of adjacent ladders in a same Control Ring. Such offset is a potential threat to the reliability of the transmission of the single-ended Reset sign...

Descripción completa

Detalles Bibliográficos
Autor principal: Wertelaers, P
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/1247551
_version_ 1780919543142547456
author Wertelaers, P
author_facet Wertelaers, P
author_sort Wertelaers, P
collection CERN
description There is no strong DC link between the individual modules, "ladders" of the Preshower. Non-negligible DC-offsets may occur between the grounds of adjacent ladders in a same Control Ring. Such offset is a potential threat to the reliability of the transmission of the single-ended Reset signal between these ladders. With a computational model, it is shown that the possible offsets we may obtain, are still on the safe side. Hence, confusing extra connectivity is not needed.
id cern-1247551
institution Organización Europea para la Investigación Nuclear
publishDate 2004
record_format invenio
spelling cern-12475512019-09-30T06:29:59Zhttp://cds.cern.ch/record/1247551Wertelaers, PThe robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS PreshowerDetectors and Experimental TechniquesThere is no strong DC link between the individual modules, "ladders" of the Preshower. Non-negligible DC-offsets may occur between the grounds of adjacent ladders in a same Control Ring. Such offset is a potential threat to the reliability of the transmission of the single-ended Reset signal between these ladders. With a computational model, it is shown that the possible offsets we may obtain, are still on the safe side. Hence, confusing extra connectivity is not needed.PH-EP-Tech-Note-2010-001oai:cds.cern.ch:12475512004-11-10
spellingShingle Detectors and Experimental Techniques
Wertelaers, P
The robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS Preshower
title The robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS Preshower
title_full The robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS Preshower
title_fullStr The robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS Preshower
title_full_unstemmed The robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS Preshower
title_short The robustness of transmission of the single-ended "reset" signal through the Token Ring of the CMS Preshower
title_sort robustness of transmission of the single-ended "reset" signal through the token ring of the cms preshower
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1247551
work_keys_str_mv AT wertelaersp therobustnessoftransmissionofthesingleendedresetsignalthroughthetokenringofthecmspreshower
AT wertelaersp robustnessoftransmissionofthesingleendedresetsignalthroughthetokenringofthecmspreshower