How would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?

Late 2002, the question arose to CMS Management if direct evaporation should not be considered for the silicon-based subsystems Tracker and Preshower. This Note discusses what would be the consequences of such scheme to Preshower design and operation. Finally, the evaporative scheme has not been ret...

Descripción completa

Detalles Bibliográficos
Autor principal: Wertelaers, P
Publicado: 2010
Materias:
Acceso en línea:http://cds.cern.ch/record/1247554
_version_ 1780919543355408384
author Wertelaers, P
author_facet Wertelaers, P
author_sort Wertelaers, P
collection CERN
description Late 2002, the question arose to CMS Management if direct evaporation should not be considered for the silicon-based subsystems Tracker and Preshower. This Note discusses what would be the consequences of such scheme to Preshower design and operation. Finally, the evaporative scheme has not been retained for CMS. Even so, certain elements in the Note may be of a more general interest.
id cern-1247554
institution Organización Europea para la Investigación Nuclear
publishDate 2010
record_format invenio
spelling cern-12475542019-09-30T06:29:59Zhttp://cds.cern.ch/record/1247554Wertelaers, PHow would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?Detectors and Experimental TechniquesLate 2002, the question arose to CMS Management if direct evaporation should not be considered for the silicon-based subsystems Tracker and Preshower. This Note discusses what would be the consequences of such scheme to Preshower design and operation. Finally, the evaporative scheme has not been retained for CMS. Even so, certain elements in the Note may be of a more general interest.PH-EP-Tech-Note-2010-002oai:cds.cern.ch:12475542010-03-08
spellingShingle Detectors and Experimental Techniques
Wertelaers, P
How would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?
title How would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?
title_full How would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?
title_fullStr How would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?
title_full_unstemmed How would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?
title_short How would the CMS Preshower behave in case of an (imaginary) evaporative cooling ?
title_sort how would the cms preshower behave in case of an (imaginary) evaporative cooling ?
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1247554
work_keys_str_mv AT wertelaersp howwouldthecmspreshowerbehaveincaseofanimaginaryevaporativecooling