Cargando…
CMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ?
The possible consequences of magnetic pick-up on a loop created by two power return conductors to same supply, are discussed. Such mechanism could drive AC ground disturbances between modules in a same Control Ring. Frequency response functions are established from a computational model.
Autor principal: | |
---|---|
Publicado: |
2010
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1247555 |
_version_ | 1780919543566172160 |
---|---|
author | Wertelaers, P |
author_facet | Wertelaers, P |
author_sort | Wertelaers, P |
collection | CERN |
description | The possible consequences of magnetic pick-up on a loop created by two power return conductors to same supply, are discussed. Such mechanism could drive AC ground disturbances between modules in a same Control Ring. Frequency response functions are established from a computational model. |
id | cern-1247555 |
institution | Organización Europea para la Investigación Nuclear |
publishDate | 2010 |
record_format | invenio |
spelling | cern-12475552019-09-30T06:29:59Zhttp://cds.cern.ch/record/1247555Wertelaers, PCMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ?Detectors and Experimental TechniquesThe possible consequences of magnetic pick-up on a loop created by two power return conductors to same supply, are discussed. Such mechanism could drive AC ground disturbances between modules in a same Control Ring. Frequency response functions are established from a computational model.PH-EP-Tech-Note-2010-003oai:cds.cern.ch:12475552010-03-08 |
spellingShingle | Detectors and Experimental Techniques Wertelaers, P CMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ? |
title | CMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ? |
title_full | CMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ? |
title_fullStr | CMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ? |
title_full_unstemmed | CMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ? |
title_short | CMS Preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ? |
title_sort | cms preshower powering : more than one feedthrough hanging on a power supply, what about ground loop ? |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1247555 |
work_keys_str_mv | AT wertelaersp cmspreshowerpoweringmorethanonefeedthroughhangingonapowersupplywhataboutgroundloop |