Voltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samples

This Note reports on the first extensive electrical measurements done on the regulator, with special attention to the behaviour of the auxiliary ports.

Detalles Bibliográficos
Autor principal: Wertelaers, P
Publicado: 2010
Materias:
Acceso en línea:http://cds.cern.ch/record/1247558
_version_ 1780919544212094976
author Wertelaers, P
author_facet Wertelaers, P
author_sort Wertelaers, P
collection CERN
description This Note reports on the first extensive electrical measurements done on the regulator, with special attention to the behaviour of the auxiliary ports.
id cern-1247558
institution Organización Europea para la Investigación Nuclear
publishDate 2010
record_format invenio
spelling cern-12475582019-09-30T06:29:59Zhttp://cds.cern.ch/record/1247558Wertelaers, PVoltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samplesDetectors and Experimental TechniquesThis Note reports on the first extensive electrical measurements done on the regulator, with special attention to the behaviour of the auxiliary ports.PH-EP-Tech-Note-2010-006oai:cds.cern.ch:12475582010-03-08
spellingShingle Detectors and Experimental Techniques
Wertelaers, P
Voltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samples
title Voltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samples
title_full Voltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samples
title_fullStr Voltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samples
title_full_unstemmed Voltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samples
title_short Voltage regulator for on-board CMS ECAL powering : selected DC tests on non-irradiated and high-fluence neutron-irradiated samples
title_sort voltage regulator for on-board cms ecal powering : selected dc tests on non-irradiated and high-fluence neutron-irradiated samples
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1247558
work_keys_str_mv AT wertelaersp voltageregulatorforonboardcmsecalpoweringselecteddctestsonnonirradiatedandhighfluenceneutronirradiatedsamples