Cargando…

Radiopurity of Micromegas readout planes

Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time Projection Chambers (TPCs) in the field of Rare Event searches (d...

Descripción completa

Detalles Bibliográficos
Autores principales: Cebrian, S, Dafni, T, Ferrer-Ribas, E, Galan, J, Giomataris, I, Gomez, H, Iguaz, F J, Irastorza, I G, Luzon, G, de Oliveira, R, Rodriguez, A, Segui, L, Tomas, A, Villar, J A
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.astropartphys.2010.09.003
http://cds.cern.ch/record/1265261
_version_ 1780920073732489216
author Cebrian, S
Dafni, T
Ferrer-Ribas, E
Galan, J
Giomataris, I
Gomez, H
Iguaz, F J
Irastorza, I G
Luzon, G
de Oliveira, R
Rodriguez, A
Segui, L
Tomas, A
Villar, J A
author_facet Cebrian, S
Dafni, T
Ferrer-Ribas, E
Galan, J
Giomataris, I
Gomez, H
Iguaz, F J
Irastorza, I G
Luzon, G
de Oliveira, R
Rodriguez, A
Segui, L
Tomas, A
Villar, J A
author_sort Cebrian, S
collection CERN
description Micromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time Projection Chambers (TPCs) in the field of Rare Event searches (dealing with dark matter, axions or double beta decay). In these experiments, the radiopurity of the detector components and surrounding materials is measured and finely controlled in order to keep the experimental background as low as possible. In the present paper, the first measurement of the radiopurity of Micromegas planes obtained by high purity germanium spectrometry in the low background facilities of the Canfranc Underground Laboratory (LSC) is presented. The obtained results prove that Micromegas readouts of the microbulk type are currently manufactured with radiopurity levels below 30 microBq/cm2 for Th and U chains and ~60 microBq/cm2 for 40K, already comparable to the cleanest detector components of the most stringent low background experiments at present. Taking into account that the studied readouts were manufactured without any specific control of the radiopurity, it should be possible to improve these levels after dedicated development.
id cern-1265261
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-12652612019-09-30T06:29:59Zdoi:10.1016/j.astropartphys.2010.09.003http://cds.cern.ch/record/1265261engCebrian, SDafni, TFerrer-Ribas, EGalan, JGiomataris, IGomez, HIguaz, F JIrastorza, I GLuzon, Gde Oliveira, RRodriguez, ASegui, LTomas, AVillar, J ARadiopurity of Micromegas readout planesDetectors and Experimental TechniquesMicromesh Gas Amplification Structures (Micromegas) are being used in an increasing number of Particle Physics applications since their conception fourteen years ago. More recently, they are being used or considered as readout of Time Projection Chambers (TPCs) in the field of Rare Event searches (dealing with dark matter, axions or double beta decay). In these experiments, the radiopurity of the detector components and surrounding materials is measured and finely controlled in order to keep the experimental background as low as possible. In the present paper, the first measurement of the radiopurity of Micromegas planes obtained by high purity germanium spectrometry in the low background facilities of the Canfranc Underground Laboratory (LSC) is presented. The obtained results prove that Micromegas readouts of the microbulk type are currently manufactured with radiopurity levels below 30 microBq/cm2 for Th and U chains and ~60 microBq/cm2 for 40K, already comparable to the cleanest detector components of the most stringent low background experiments at present. Taking into account that the studied readouts were manufactured without any specific control of the radiopurity, it should be possible to improve these levels after dedicated development.arXiv:1005.2022oai:cds.cern.ch:12652612010-05-13
spellingShingle Detectors and Experimental Techniques
Cebrian, S
Dafni, T
Ferrer-Ribas, E
Galan, J
Giomataris, I
Gomez, H
Iguaz, F J
Irastorza, I G
Luzon, G
de Oliveira, R
Rodriguez, A
Segui, L
Tomas, A
Villar, J A
Radiopurity of Micromegas readout planes
title Radiopurity of Micromegas readout planes
title_full Radiopurity of Micromegas readout planes
title_fullStr Radiopurity of Micromegas readout planes
title_full_unstemmed Radiopurity of Micromegas readout planes
title_short Radiopurity of Micromegas readout planes
title_sort radiopurity of micromegas readout planes
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.astropartphys.2010.09.003
http://cds.cern.ch/record/1265261
work_keys_str_mv AT cebrians radiopurityofmicromegasreadoutplanes
AT dafnit radiopurityofmicromegasreadoutplanes
AT ferrerribase radiopurityofmicromegasreadoutplanes
AT galanj radiopurityofmicromegasreadoutplanes
AT giomatarisi radiopurityofmicromegasreadoutplanes
AT gomezh radiopurityofmicromegasreadoutplanes
AT iguazfj radiopurityofmicromegasreadoutplanes
AT irastorzaig radiopurityofmicromegasreadoutplanes
AT luzong radiopurityofmicromegasreadoutplanes
AT deoliveirar radiopurityofmicromegasreadoutplanes
AT rodrigueza radiopurityofmicromegasreadoutplanes
AT seguil radiopurityofmicromegasreadoutplanes
AT tomasa radiopurityofmicromegasreadoutplanes
AT villarja radiopurityofmicromegasreadoutplanes