Cargando…

Determination of the Absolute Light Yields of LuYAP and LYSO

The results of light yield (LY) measurements of 2 x 2 x 8 mm(3) and 2 x 2 x 10 mm(3) LuYAP and LYSO pixels are compared with Monte-Carlo simulations of equivalent systems performed with the light ray tracing program LITRANI. It is shown that the differences in LY observed for different setup configu...

Descripción completa

Detalles Bibliográficos
Autores principales: Kronberger, Matthias, Auffray, Etiennette, Lecoq, Paul
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1267944
_version_ 1780920131239542784
author Kronberger, Matthias
Auffray, Etiennette
Lecoq, Paul
author_facet Kronberger, Matthias
Auffray, Etiennette
Lecoq, Paul
author_sort Kronberger, Matthias
collection CERN
description The results of light yield (LY) measurements of 2 x 2 x 8 mm(3) and 2 x 2 x 10 mm(3) LuYAP and LYSO pixels are compared with Monte-Carlo simulations of equivalent systems performed with the light ray tracing program LITRANI. It is shown that the differences in LY observed for different setup configurations are well explained by the different light collection efficiencies eta L of the setups derived from the simulations. Combining the results on LY and eta L for a reference system makes it possible to determine the absolute light yield LYabs for LuYAP and LYSO.
id cern-1267944
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-12679442019-09-30T06:29:59Zhttp://cds.cern.ch/record/1267944engKronberger, MatthiasAuffray, EtiennetteLecoq, PaulDetermination of the Absolute Light Yields of LuYAP and LYSOHealth Physics and Radiation EffectsThe results of light yield (LY) measurements of 2 x 2 x 8 mm(3) and 2 x 2 x 10 mm(3) LuYAP and LYSO pixels are compared with Monte-Carlo simulations of equivalent systems performed with the light ray tracing program LITRANI. It is shown that the differences in LY observed for different setup configurations are well explained by the different light collection efficiencies eta L of the setups derived from the simulations. Combining the results on LY and eta L for a reference system makes it possible to determine the absolute light yield LYabs for LuYAP and LYSO.oai:cds.cern.ch:12679442009
spellingShingle Health Physics and Radiation Effects
Kronberger, Matthias
Auffray, Etiennette
Lecoq, Paul
Determination of the Absolute Light Yields of LuYAP and LYSO
title Determination of the Absolute Light Yields of LuYAP and LYSO
title_full Determination of the Absolute Light Yields of LuYAP and LYSO
title_fullStr Determination of the Absolute Light Yields of LuYAP and LYSO
title_full_unstemmed Determination of the Absolute Light Yields of LuYAP and LYSO
title_short Determination of the Absolute Light Yields of LuYAP and LYSO
title_sort determination of the absolute light yields of luyap and lyso
topic Health Physics and Radiation Effects
url http://cds.cern.ch/record/1267944
work_keys_str_mv AT kronbergermatthias determinationoftheabsolutelightyieldsofluyapandlyso
AT auffrayetiennette determinationoftheabsolutelightyieldsofluyapandlyso
AT lecoqpaul determinationoftheabsolutelightyieldsofluyapandlyso