Determination of the Absolute Light Yields of LuYAP and LYSO
The results of light yield (LY) measurements of 2 x 2 x 8 mm(3) and 2 x 2 x 10 mm(3) LuYAP and LYSO pixels are compared with Monte-Carlo simulations of equivalent systems performed with the light ray tracing program LITRANI. It is shown that the differences in LY observed for different setup configu...
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1267944 |
_version_ | 1780920131239542784 |
---|---|
author | Kronberger, Matthias Auffray, Etiennette Lecoq, Paul |
author_facet | Kronberger, Matthias Auffray, Etiennette Lecoq, Paul |
author_sort | Kronberger, Matthias |
collection | CERN |
description | The results of light yield (LY) measurements of 2 x 2 x 8 mm(3) and 2 x 2 x 10 mm(3) LuYAP and LYSO pixels are compared with Monte-Carlo simulations of equivalent systems performed with the light ray tracing program LITRANI. It is shown that the differences in LY observed for different setup configurations are well explained by the different light collection efficiencies eta L of the setups derived from the simulations. Combining the results on LY and eta L for a reference system makes it possible to determine the absolute light yield LYabs for LuYAP and LYSO. |
id | cern-1267944 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2009 |
record_format | invenio |
spelling | cern-12679442019-09-30T06:29:59Zhttp://cds.cern.ch/record/1267944engKronberger, MatthiasAuffray, EtiennetteLecoq, PaulDetermination of the Absolute Light Yields of LuYAP and LYSOHealth Physics and Radiation EffectsThe results of light yield (LY) measurements of 2 x 2 x 8 mm(3) and 2 x 2 x 10 mm(3) LuYAP and LYSO pixels are compared with Monte-Carlo simulations of equivalent systems performed with the light ray tracing program LITRANI. It is shown that the differences in LY observed for different setup configurations are well explained by the different light collection efficiencies eta L of the setups derived from the simulations. Combining the results on LY and eta L for a reference system makes it possible to determine the absolute light yield LYabs for LuYAP and LYSO.oai:cds.cern.ch:12679442009 |
spellingShingle | Health Physics and Radiation Effects Kronberger, Matthias Auffray, Etiennette Lecoq, Paul Determination of the Absolute Light Yields of LuYAP and LYSO |
title | Determination of the Absolute Light Yields of LuYAP and LYSO |
title_full | Determination of the Absolute Light Yields of LuYAP and LYSO |
title_fullStr | Determination of the Absolute Light Yields of LuYAP and LYSO |
title_full_unstemmed | Determination of the Absolute Light Yields of LuYAP and LYSO |
title_short | Determination of the Absolute Light Yields of LuYAP and LYSO |
title_sort | determination of the absolute light yields of luyap and lyso |
topic | Health Physics and Radiation Effects |
url | http://cds.cern.ch/record/1267944 |
work_keys_str_mv | AT kronbergermatthias determinationoftheabsolutelightyieldsofluyapandlyso AT auffrayetiennette determinationoftheabsolutelightyieldsofluyapandlyso AT lecoqpaul determinationoftheabsolutelightyieldsofluyapandlyso |