Cargando…
Low-Power Amplifier-Discriminators for High Time Resolution Detection
Low-power amplifier-discriminators based on a so-called NINO architecture have been developed with high time resolution for the readout of radiation detectors. Two different circuits were integrated in the NINO13 chip, processed in IBM 130 nm CMOS technology. The LCO version (Low Capacitance and con...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2009
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2009.2013350 http://cds.cern.ch/record/1267949 |
_version_ | 1780920132353130496 |
---|---|
author | Despeisse, M Jarron, P Anghinolfi, F Tiuraniemi, S Osmic, F Riedler, P Kluge, A Ceccucci, A |
author_facet | Despeisse, M Jarron, P Anghinolfi, F Tiuraniemi, S Osmic, F Riedler, P Kluge, A Ceccucci, A |
author_sort | Despeisse, M |
collection | CERN |
description | Low-power amplifier-discriminators based on a so-called NINO architecture have been developed with high time resolution for the readout of radiation detectors. Two different circuits were integrated in the NINO13 chip, processed in IBM 130 nm CMOS technology. The LCO version (Low Capacitance and consumption Optimization) was designed for potential use as front-end electronics in the Gigatracker of the NA62 experiment at CERN. It was developed as pixel readout for solid-state pixel detectors to permit minimum ionizing particle detection with less than 180 ps rms resolution per pixel on the output pulse, for power consumption below 300 mu W per pixel. The HCO version (High Capacitance Optimization) was designed with 4 mW power consumption per channel to provide timing resolution below 20 ps rms on the output pulse, for charges above 10 fC. Results presented show the potential of the LCO and HCO circuits for the precise timing readout of solid-state detectors, vacuum tubes or gas detectors, for applications in high energy physics, biotechnologies or medical imaging. |
id | cern-1267949 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2009 |
record_format | invenio |
spelling | cern-12679492019-09-30T06:29:59Zdoi:10.1109/TNS.2009.2013350http://cds.cern.ch/record/1267949engDespeisse, MJarron, PAnghinolfi, FTiuraniemi, SOsmic, FRiedler, PKluge, ACeccucci, ALow-Power Amplifier-Discriminators for High Time Resolution DetectionDetectors and Experimental TechniquesLow-power amplifier-discriminators based on a so-called NINO architecture have been developed with high time resolution for the readout of radiation detectors. Two different circuits were integrated in the NINO13 chip, processed in IBM 130 nm CMOS technology. The LCO version (Low Capacitance and consumption Optimization) was designed for potential use as front-end electronics in the Gigatracker of the NA62 experiment at CERN. It was developed as pixel readout for solid-state pixel detectors to permit minimum ionizing particle detection with less than 180 ps rms resolution per pixel on the output pulse, for power consumption below 300 mu W per pixel. The HCO version (High Capacitance Optimization) was designed with 4 mW power consumption per channel to provide timing resolution below 20 ps rms on the output pulse, for charges above 10 fC. Results presented show the potential of the LCO and HCO circuits for the precise timing readout of solid-state detectors, vacuum tubes or gas detectors, for applications in high energy physics, biotechnologies or medical imaging.oai:cds.cern.ch:12679492009 |
spellingShingle | Detectors and Experimental Techniques Despeisse, M Jarron, P Anghinolfi, F Tiuraniemi, S Osmic, F Riedler, P Kluge, A Ceccucci, A Low-Power Amplifier-Discriminators for High Time Resolution Detection |
title | Low-Power Amplifier-Discriminators for High Time Resolution Detection |
title_full | Low-Power Amplifier-Discriminators for High Time Resolution Detection |
title_fullStr | Low-Power Amplifier-Discriminators for High Time Resolution Detection |
title_full_unstemmed | Low-Power Amplifier-Discriminators for High Time Resolution Detection |
title_short | Low-Power Amplifier-Discriminators for High Time Resolution Detection |
title_sort | low-power amplifier-discriminators for high time resolution detection |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/TNS.2009.2013350 http://cds.cern.ch/record/1267949 |
work_keys_str_mv | AT despeissem lowpoweramplifierdiscriminatorsforhightimeresolutiondetection AT jarronp lowpoweramplifierdiscriminatorsforhightimeresolutiondetection AT anghinolfif lowpoweramplifierdiscriminatorsforhightimeresolutiondetection AT tiuraniemis lowpoweramplifierdiscriminatorsforhightimeresolutiondetection AT osmicf lowpoweramplifierdiscriminatorsforhightimeresolutiondetection AT riedlerp lowpoweramplifierdiscriminatorsforhightimeresolutiondetection AT klugea lowpoweramplifierdiscriminatorsforhightimeresolutiondetection AT ceccuccia lowpoweramplifierdiscriminatorsforhightimeresolutiondetection |