Cargando…

Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics

One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagno...

Descripción completa

Detalles Bibliográficos
Autores principales: Gerstl, Stefan, Baumbach, Tilo, Casalbuoni, Sara, Grau, Andreas, Hagelstein, Michael, Saez de Jauregui, David, Baglin, Vincent, Boffo, Cristian, Sikler, Gunther, Bradshaw, Thomas, Cimino, Roberto, Commisso, Mario, Spataro, Bruno, Clarke, James, Scott, Duncan, Cox, Matthew, Schouten, Jos, Jones, Roger, Shinton, Ian, Mostacci, Andrea, Wallen, Erik, Weigel, Ralf
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:http://cds.cern.ch/record/1269156
_version_ 1780920157775855616
author Gerstl, Stefan
Baumbach, Tilo
Casalbuoni, Sara
Grau, Andreas
Hagelstein, Michael
Saez de Jauregui, David
Baglin, Vincent
Boffo, Cristian
Sikler, Gunther
Bradshaw, Thomas
Cimino, Roberto
Commisso, Mario
Spataro, Bruno
Clarke, James
Scott, Duncan
Cox, Matthew
Schouten, Jos
Jones, Roger
Shinton, Ian
Mostacci, Andrea
Wallen, Erik
Weigel, Ralf
author_facet Gerstl, Stefan
Baumbach, Tilo
Casalbuoni, Sara
Grau, Andreas
Hagelstein, Michael
Saez de Jauregui, David
Baglin, Vincent
Boffo, Cristian
Sikler, Gunther
Bradshaw, Thomas
Cimino, Roberto
Commisso, Mario
Spataro, Bruno
Clarke, James
Scott, Duncan
Cox, Matthew
Schouten, Jos
Jones, Roger
Shinton, Ian
Mostacci, Andrea
Wallen, Erik
Weigel, Ralf
author_sort Gerstl, Stefan
collection CERN
description One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.
id cern-1269156
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-12691562023-05-30T02:17:10Zhttp://cds.cern.ch/record/1269156engGerstl, StefanBaumbach, TiloCasalbuoni, SaraGrau, AndreasHagelstein, MichaelSaez de Jauregui, DavidBaglin, VincentBoffo, CristianSikler, GuntherBradshaw, ThomasCimino, RobertoCommisso, MarioSpataro, BrunoClarke, JamesScott, DuncanCox, MatthewSchouten, JosJones, RogerShinton, IanMostacci, AndreaWallen, ErikWeigel, RalfStatus of COLDDIAG: A Cold Vacuum Chamber for DiagnosticsAccelerators and Storage RingsOne of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.arXiv:1006.0089IPAC-2010-WEPD018oai:cds.cern.ch:12691562010-06-02
spellingShingle Accelerators and Storage Rings
Gerstl, Stefan
Baumbach, Tilo
Casalbuoni, Sara
Grau, Andreas
Hagelstein, Michael
Saez de Jauregui, David
Baglin, Vincent
Boffo, Cristian
Sikler, Gunther
Bradshaw, Thomas
Cimino, Roberto
Commisso, Mario
Spataro, Bruno
Clarke, James
Scott, Duncan
Cox, Matthew
Schouten, Jos
Jones, Roger
Shinton, Ian
Mostacci, Andrea
Wallen, Erik
Weigel, Ralf
Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_full Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_fullStr Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_full_unstemmed Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_short Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics
title_sort status of colddiag: a cold vacuum chamber for diagnostics
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1269156
work_keys_str_mv AT gerstlstefan statusofcolddiagacoldvacuumchamberfordiagnostics
AT baumbachtilo statusofcolddiagacoldvacuumchamberfordiagnostics
AT casalbuonisara statusofcolddiagacoldvacuumchamberfordiagnostics
AT grauandreas statusofcolddiagacoldvacuumchamberfordiagnostics
AT hagelsteinmichael statusofcolddiagacoldvacuumchamberfordiagnostics
AT saezdejaureguidavid statusofcolddiagacoldvacuumchamberfordiagnostics
AT baglinvincent statusofcolddiagacoldvacuumchamberfordiagnostics
AT boffocristian statusofcolddiagacoldvacuumchamberfordiagnostics
AT siklergunther statusofcolddiagacoldvacuumchamberfordiagnostics
AT bradshawthomas statusofcolddiagacoldvacuumchamberfordiagnostics
AT ciminoroberto statusofcolddiagacoldvacuumchamberfordiagnostics
AT commissomario statusofcolddiagacoldvacuumchamberfordiagnostics
AT spatarobruno statusofcolddiagacoldvacuumchamberfordiagnostics
AT clarkejames statusofcolddiagacoldvacuumchamberfordiagnostics
AT scottduncan statusofcolddiagacoldvacuumchamberfordiagnostics
AT coxmatthew statusofcolddiagacoldvacuumchamberfordiagnostics
AT schoutenjos statusofcolddiagacoldvacuumchamberfordiagnostics
AT jonesroger statusofcolddiagacoldvacuumchamberfordiagnostics
AT shintonian statusofcolddiagacoldvacuumchamberfordiagnostics
AT mostacciandrea statusofcolddiagacoldvacuumchamberfordiagnostics
AT wallenerik statusofcolddiagacoldvacuumchamberfordiagnostics
AT weigelralf statusofcolddiagacoldvacuumchamberfordiagnostics