The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred fr...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1271733 |
_version_ | 1780920229565562880 |
---|---|
author | Sapinski, M Dehning, B Holzer, EB Jonker, M Mallows, S Otto, T Welsch, C |
author_facet | Sapinski, M Dehning, B Holzer, EB Jonker, M Mallows, S Otto, T Welsch, C |
author_sort | Sapinski, M |
collection | CERN |
description | The Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied. |
id | cern-1271733 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-12717332022-08-17T13:26:54Zhttp://cds.cern.ch/record/1271733engSapinski, MDehning, BHolzer, EBJonker, MMallows, SOtto, TWelsch, CRequirements of CLIC Beam Loss Monitoring SystemAccelerators and Storage RingsThe Compact Linear Collider (CLIC) [1] is a proposed multi-TeV linear electron-positron collider being designed by a world-wide collaboration. It is based on a novel twobeam acceleration scheme in which two beams (drive and main beam) are placed in parallel to each other and energy is transferred from the drive beam to the main one. Beam losses on either of them can have catastrophic consequences for the machine, because of high intensity (drive beam) or high energy and small emittance (main beam). In the framework of machine protection, a Beam Loss Monitoring (BLM) system has to be put in place. This paper discusses the requirements for the beam loss system in terms of detector sensitivity, resolution, dynamic range and ability to distinguish losses originating from various sources. The two-beam module where the protection from beam losses is particularly challenging and important, is studied.CERN-ATS-2010-105oai:cds.cern.ch:12717332010-06-14 |
spellingShingle | Accelerators and Storage Rings Sapinski, M Dehning, B Holzer, EB Jonker, M Mallows, S Otto, T Welsch, C Requirements of CLIC Beam Loss Monitoring System |
title | Requirements of CLIC Beam Loss Monitoring System |
title_full | Requirements of CLIC Beam Loss Monitoring System |
title_fullStr | Requirements of CLIC Beam Loss Monitoring System |
title_full_unstemmed | Requirements of CLIC Beam Loss Monitoring System |
title_short | Requirements of CLIC Beam Loss Monitoring System |
title_sort | requirements of clic beam loss monitoring system |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1271733 |
work_keys_str_mv | AT sapinskim requirementsofclicbeamlossmonitoringsystem AT dehningb requirementsofclicbeamlossmonitoringsystem AT holzereb requirementsofclicbeamlossmonitoringsystem AT jonkerm requirementsofclicbeamlossmonitoringsystem AT mallowss requirementsofclicbeamlossmonitoringsystem AT ottot requirementsofclicbeamlossmonitoringsystem AT welschc requirementsofclicbeamlossmonitoringsystem |