Scintillator-Based Electromagnetic Calorimeter Prototype and Beam Test Results at FNAL
A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with hadronic calorimeter and Tail catcher. One of the main objecti...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1278338 |
Sumario: | A prototype Scintillator-Tungsten electromagnetic calorimeter (ScECAL) for the ILC detector was tested in 2008 at the Fermilab test beam. Data were collected with electron, pion and muon beams in the energy range 1 to 32GeV combined with hadronic calorimeter and Tail catcher. One of the main objectives of the CALICE program is to establish the technology of Scintillator-based electromagnetic calorimeter and validate the prformance of the calorimeter. From preliminary results of the first approach of analysis with electron beam, we obtain the ScECAL energy resolution {\sigma}stochastic = 15.15+/-0.03% and {\sigma}constant = 1.44+/-0.02% . The deviation from the linear response is calculated to be less than 6%. |
---|