Cargando…
Beam interlock system and safe machine parameters system: 2010 and beyond
The Beam Interlock System (BIS) and Safe Machine Parameters (SMP) system are central to the protection of the Large Hadron Collider (LHC) machine. The BIS has been critical for the safe operation of LHC from the first day of operation. It has been installed and commissioned, only minor enhancements...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1281627 |
_version_ | 1780920476545056768 |
---|---|
author | Todd, B Puccio, B |
author_facet | Todd, B Puccio, B |
author_sort | Todd, B |
collection | CERN |
description | The Beam Interlock System (BIS) and Safe Machine Parameters (SMP) system are central to the protection of the Large Hadron Collider (LHC) machine. The BIS has been critical for the safe operation of LHC from the first day of operation. It has been installed and commissioned, only minor enhancements are required in order to accommodate all future LHC machine protection requirements. At reduced intensity, the SMP system is less critical for LHC operation. As such, the current system satisfies the 2010 operational requirements. Further developments are required, both at the SMP Controller level, and at the system level, in order to accommodate the requirements of the LHC beyond 2010. |
id | cern-1281627 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-12816272021-09-14T11:41:57Zhttp://cds.cern.ch/record/1281627engTodd, BPuccio, BBeam interlock system and safe machine parameters system: 2010 and beyondAccelerators and Storage RingsThe Beam Interlock System (BIS) and Safe Machine Parameters (SMP) system are central to the protection of the Large Hadron Collider (LHC) machine. The BIS has been critical for the safe operation of LHC from the first day of operation. It has been installed and commissioned, only minor enhancements are required in order to accommodate all future LHC machine protection requirements. At reduced intensity, the SMP system is less critical for LHC operation. As such, the current system satisfies the 2010 operational requirements. Further developments are required, both at the SMP Controller level, and at the system level, in order to accommodate the requirements of the LHC beyond 2010.oai:cds.cern.ch:12816272010 |
spellingShingle | Accelerators and Storage Rings Todd, B Puccio, B Beam interlock system and safe machine parameters system: 2010 and beyond |
title | Beam interlock system and safe machine parameters system: 2010 and beyond |
title_full | Beam interlock system and safe machine parameters system: 2010 and beyond |
title_fullStr | Beam interlock system and safe machine parameters system: 2010 and beyond |
title_full_unstemmed | Beam interlock system and safe machine parameters system: 2010 and beyond |
title_short | Beam interlock system and safe machine parameters system: 2010 and beyond |
title_sort | beam interlock system and safe machine parameters system: 2010 and beyond |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1281627 |
work_keys_str_mv | AT toddb beaminterlocksystemandsafemachineparameterssystem2010andbeyond AT pucciob beaminterlocksystemandsafemachineparameterssystem2010andbeyond |