Cargando…

The ATLAS Liquid Argon Calorimeter at the LHC: Overview and Performance

The Liquid Argon (LAr) Calorimeters provide electromagnetic and forward hadronic calorimetry measurements for the ATLAS experiment. Since 2008, all parts of the LAr calorimeters are readout. An overview of the LAr calorimeters, including hardware status and performance of the calibration system and...

Descripción completa

Detalles Bibliográficos
Autor principal: Aurousseau, M
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nuclphysbps.2011.03.150
http://cds.cern.ch/record/1284259
_version_ 1780920544141508608
author Aurousseau, M
author_facet Aurousseau, M
author_sort Aurousseau, M
collection CERN
description The Liquid Argon (LAr) Calorimeters provide electromagnetic and forward hadronic calorimetry measurements for the ATLAS experiment. Since 2008, all parts of the LAr calorimeters are readout. An overview of the LAr calorimeters, including hardware status and performance of the calibration system and calorimeter trigger, is presented. Results on timing alignment, uniformity and energy flow, extracted from cosmics and collision data, are presented and show the excellent performance of the LAr calorimeters 3 months after the start of LHC operation at 7 ev{} energy in center of mass.
id cern-1284259
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-12842592019-09-30T06:29:59Zdoi:10.1016/j.nuclphysbps.2011.03.150http://cds.cern.ch/record/1284259engAurousseau, MThe ATLAS Liquid Argon Calorimeter at the LHC: Overview and PerformanceDetectors and Experimental TechniquesThe Liquid Argon (LAr) Calorimeters provide electromagnetic and forward hadronic calorimetry measurements for the ATLAS experiment. Since 2008, all parts of the LAr calorimeters are readout. An overview of the LAr calorimeters, including hardware status and performance of the calibration system and calorimeter trigger, is presented. Results on timing alignment, uniformity and energy flow, extracted from cosmics and collision data, are presented and show the excellent performance of the LAr calorimeters 3 months after the start of LHC operation at 7 ev{} energy in center of mass.ATL-LARG-PROC-2010-005oai:cds.cern.ch:12842592010-08-10
spellingShingle Detectors and Experimental Techniques
Aurousseau, M
The ATLAS Liquid Argon Calorimeter at the LHC: Overview and Performance
title The ATLAS Liquid Argon Calorimeter at the LHC: Overview and Performance
title_full The ATLAS Liquid Argon Calorimeter at the LHC: Overview and Performance
title_fullStr The ATLAS Liquid Argon Calorimeter at the LHC: Overview and Performance
title_full_unstemmed The ATLAS Liquid Argon Calorimeter at the LHC: Overview and Performance
title_short The ATLAS Liquid Argon Calorimeter at the LHC: Overview and Performance
title_sort atlas liquid argon calorimeter at the lhc: overview and performance
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nuclphysbps.2011.03.150
http://cds.cern.ch/record/1284259
work_keys_str_mv AT aurousseaum theatlasliquidargoncalorimeteratthelhcoverviewandperformance
AT aurousseaum atlasliquidargoncalorimeteratthelhcoverviewandperformance