Cargando…

A 12 GHZ RF Power source for the CLIC study

The CLIC RF frequency has been changed in 2008 from the initial 30 GHz to the European X-band 11.9942 GHz permitting beam independent power production using klystrons for CLIC accelerating structure testing. A design and fabrication contract for five klystrons at that frequency has been signed by di...

Descripción completa

Detalles Bibliográficos
Autores principales: Peauger, F, Hamdi, A, Curt, S, Doebert, S, McMonagle, G, Rossat, G, Schirm, KM, Syratchev, I, Timeo, L, Kuzikhov, S, Vikharev, AA, Haase, A, Sprehn, D, Jensen, A, Jongewaard, EN, Nantista, CD, Vlieks, A
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:http://cds.cern.ch/record/1287901
_version_ 1780920625354768384
author Peauger, F
Hamdi, A
Curt, S
Doebert, S
McMonagle, G
Rossat, G
Schirm, KM
Syratchev, I
Timeo, L
Kuzikhov, S
Vikharev, AA
Haase, A
Sprehn, D
Jensen, A
Jongewaard, EN
Nantista, CD
Vlieks, A
author_facet Peauger, F
Hamdi, A
Curt, S
Doebert, S
McMonagle, G
Rossat, G
Schirm, KM
Syratchev, I
Timeo, L
Kuzikhov, S
Vikharev, AA
Haase, A
Sprehn, D
Jensen, A
Jongewaard, EN
Nantista, CD
Vlieks, A
author_sort Peauger, F
collection CERN
description The CLIC RF frequency has been changed in 2008 from the initial 30 GHz to the European X-band 11.9942 GHz permitting beam independent power production using klystrons for CLIC accelerating structure testing. A design and fabrication contract for five klystrons at that frequency has been signed by different parties with SLAC. France (IRFU, CEA Saclay) is contributing a solid state modulator purchased in industry and specific 12 GHz RF network components to the CLIC study. RF pulses over 120 MW peak at 230 ns length will be obtained by using a novel SLED-I type pulse compression scheme designed and fabricated by IAP, Nizhny Novgorod, Russia. The X-band power test stand is being installed in the CLIC Test Facility CTF3 for independent structure and component testing in a bunker, but allowing, in a later stage, for powering RF components in the CTF3 beam lines. The design of the facility, results from commissioning of the RF power source and the expected performance of the Test Facility are reported.
id cern-1287901
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-12879012022-08-17T13:26:26Zhttp://cds.cern.ch/record/1287901engPeauger, FHamdi, ACurt, SDoebert, SMcMonagle, GRossat, GSchirm, KMSyratchev, ITimeo, LKuzikhov, SVikharev, AAHaase, ASprehn, DJensen, AJongewaard, ENNantista, CDVlieks, AA 12 GHZ RF Power source for the CLIC studyAccelerators and Storage RingsThe CLIC RF frequency has been changed in 2008 from the initial 30 GHz to the European X-band 11.9942 GHz permitting beam independent power production using klystrons for CLIC accelerating structure testing. A design and fabrication contract for five klystrons at that frequency has been signed by different parties with SLAC. France (IRFU, CEA Saclay) is contributing a solid state modulator purchased in industry and specific 12 GHz RF network components to the CLIC study. RF pulses over 120 MW peak at 230 ns length will be obtained by using a novel SLED-I type pulse compression scheme designed and fabricated by IAP, Nizhny Novgorod, Russia. The X-band power test stand is being installed in the CLIC Test Facility CTF3 for independent structure and component testing in a bunker, but allowing, in a later stage, for powering RF components in the CTF3 beam lines. The design of the facility, results from commissioning of the RF power source and the expected performance of the Test Facility are reported.CERN-ATS-2010-196oai:cds.cern.ch:12879012010-05-30
spellingShingle Accelerators and Storage Rings
Peauger, F
Hamdi, A
Curt, S
Doebert, S
McMonagle, G
Rossat, G
Schirm, KM
Syratchev, I
Timeo, L
Kuzikhov, S
Vikharev, AA
Haase, A
Sprehn, D
Jensen, A
Jongewaard, EN
Nantista, CD
Vlieks, A
A 12 GHZ RF Power source for the CLIC study
title A 12 GHZ RF Power source for the CLIC study
title_full A 12 GHZ RF Power source for the CLIC study
title_fullStr A 12 GHZ RF Power source for the CLIC study
title_full_unstemmed A 12 GHZ RF Power source for the CLIC study
title_short A 12 GHZ RF Power source for the CLIC study
title_sort 12 ghz rf power source for the clic study
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1287901
work_keys_str_mv AT peaugerf a12ghzrfpowersourcefortheclicstudy
AT hamdia a12ghzrfpowersourcefortheclicstudy
AT curts a12ghzrfpowersourcefortheclicstudy
AT doeberts a12ghzrfpowersourcefortheclicstudy
AT mcmonagleg a12ghzrfpowersourcefortheclicstudy
AT rossatg a12ghzrfpowersourcefortheclicstudy
AT schirmkm a12ghzrfpowersourcefortheclicstudy
AT syratchevi a12ghzrfpowersourcefortheclicstudy
AT timeol a12ghzrfpowersourcefortheclicstudy
AT kuzikhovs a12ghzrfpowersourcefortheclicstudy
AT vikharevaa a12ghzrfpowersourcefortheclicstudy
AT haasea a12ghzrfpowersourcefortheclicstudy
AT sprehnd a12ghzrfpowersourcefortheclicstudy
AT jensena a12ghzrfpowersourcefortheclicstudy
AT jongewaarden a12ghzrfpowersourcefortheclicstudy
AT nantistacd a12ghzrfpowersourcefortheclicstudy
AT vlieksa a12ghzrfpowersourcefortheclicstudy
AT peaugerf 12ghzrfpowersourcefortheclicstudy
AT hamdia 12ghzrfpowersourcefortheclicstudy
AT curts 12ghzrfpowersourcefortheclicstudy
AT doeberts 12ghzrfpowersourcefortheclicstudy
AT mcmonagleg 12ghzrfpowersourcefortheclicstudy
AT rossatg 12ghzrfpowersourcefortheclicstudy
AT schirmkm 12ghzrfpowersourcefortheclicstudy
AT syratchevi 12ghzrfpowersourcefortheclicstudy
AT timeol 12ghzrfpowersourcefortheclicstudy
AT kuzikhovs 12ghzrfpowersourcefortheclicstudy
AT vikharevaa 12ghzrfpowersourcefortheclicstudy
AT haasea 12ghzrfpowersourcefortheclicstudy
AT sprehnd 12ghzrfpowersourcefortheclicstudy
AT jensena 12ghzrfpowersourcefortheclicstudy
AT jongewaarden 12ghzrfpowersourcefortheclicstudy
AT nantistacd 12ghzrfpowersourcefortheclicstudy
AT vlieksa 12ghzrfpowersourcefortheclicstudy