Front-end electronics for the ALICE calorimeters

The ALICE calorimeters PHOS and EMCal are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSP) for readout of the scintillating elements. The amplified signals are read out via 32-channel shaper/digitizer front-end electronics (FEE) with 14-bit effective dynami...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Ya-Ping, Ma, Ke, Muller, Hans, Cai, Xu, Zhou, Daicui, Yin, Zhong-Bao, Awes, Terry C., Wang, Dong
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2009.09.022
http://cds.cern.ch/record/1290347
_version_ 1780920698820100096
author Wang, Ya-Ping
Ma, Ke
Muller, Hans
Cai, Xu
Zhou, Daicui
Yin, Zhong-Bao
Awes, Terry C.
Wang, Dong
author_facet Wang, Ya-Ping
Ma, Ke
Muller, Hans
Cai, Xu
Zhou, Daicui
Yin, Zhong-Bao
Awes, Terry C.
Wang, Dong
author_sort Wang, Ya-Ping
collection CERN
description The ALICE calorimeters PHOS and EMCal are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSP) for readout of the scintillating elements. The amplified signals are read out via 32-channel shaper/digitizer front-end electronics (FEE) with 14-bit effective dynamic range. The electronics is based on second order shapers with dual gain for each channel, getting digitized by ALTRO chips. Each APD channel is equipped with an individual 10-bit APD gain adjustment and 2×2 channel clusters generate a 100 ns shaped analog sums output (Fast OR) for the associated Trigger Region Units (TRU). The Fast OR signals are generated by first order shapers with a dynamic range of 12-bit given by the ADC in the TRU cards. Board controller firmware in the FPGA provides local monitoring and configuration of all parameters via the ALICE DCS system. The signal to noise ratio for MIP at 215 MeV is not, vert, similar7 per channel with a noise level of 30 MeV at room temperature for a dynamic range of 80 GeV for PHOS, and the fast-OR RMS noise level is about 75 MeV for a dynamic range of 250 GeV for EMCal.
id cern-1290347
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-12903472019-09-30T06:29:59Zdoi:10.1016/j.nima.2009.09.022http://cds.cern.ch/record/1290347engWang, Ya-PingMa, KeMuller, HansCai, XuZhou, DaicuiYin, Zhong-BaoAwes, Terry C.Wang, DongFront-end electronics for the ALICE calorimetersDetectors and Experimental TechniquesThe ALICE calorimeters PHOS and EMCal are based on Avalanche Photo-Diode (APD) photosensors with Charge Sensitive Preamplifiers (CSP) for readout of the scintillating elements. The amplified signals are read out via 32-channel shaper/digitizer front-end electronics (FEE) with 14-bit effective dynamic range. The electronics is based on second order shapers with dual gain for each channel, getting digitized by ALTRO chips. Each APD channel is equipped with an individual 10-bit APD gain adjustment and 2×2 channel clusters generate a 100 ns shaped analog sums output (Fast OR) for the associated Trigger Region Units (TRU). The Fast OR signals are generated by first order shapers with a dynamic range of 12-bit given by the ADC in the TRU cards. Board controller firmware in the FPGA provides local monitoring and configuration of all parameters via the ALICE DCS system. The signal to noise ratio for MIP at 215 MeV is not, vert, similar7 per channel with a noise level of 30 MeV at room temperature for a dynamic range of 80 GeV for PHOS, and the fast-OR RMS noise level is about 75 MeV for a dynamic range of 250 GeV for EMCal.oai:cds.cern.ch:12903472010
spellingShingle Detectors and Experimental Techniques
Wang, Ya-Ping
Ma, Ke
Muller, Hans
Cai, Xu
Zhou, Daicui
Yin, Zhong-Bao
Awes, Terry C.
Wang, Dong
Front-end electronics for the ALICE calorimeters
title Front-end electronics for the ALICE calorimeters
title_full Front-end electronics for the ALICE calorimeters
title_fullStr Front-end electronics for the ALICE calorimeters
title_full_unstemmed Front-end electronics for the ALICE calorimeters
title_short Front-end electronics for the ALICE calorimeters
title_sort front-end electronics for the alice calorimeters
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2009.09.022
http://cds.cern.ch/record/1290347
work_keys_str_mv AT wangyaping frontendelectronicsforthealicecalorimeters
AT make frontendelectronicsforthealicecalorimeters
AT mullerhans frontendelectronicsforthealicecalorimeters
AT caixu frontendelectronicsforthealicecalorimeters
AT zhoudaicui frontendelectronicsforthealicecalorimeters
AT yinzhongbao frontendelectronicsforthealicecalorimeters
AT awesterryc frontendelectronicsforthealicecalorimeters
AT wangdong frontendelectronicsforthealicecalorimeters