Cargando…
Accuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 Mev
The CERN LINAC4 commissioning will start in 2011, at first in a laboratory test stand where the 45 KeV Hsource is already installed and presently tested, and later in the LINAC4 tunnel. A movable diagnostics bench will be equipped with the necessary sensors capable of characterizing the H- beam in d...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1303299 |
_version_ | 1780921101839237120 |
---|---|
author | Roncarolo, F Cheymol, B Bravin, E Raich, U |
author_facet | Roncarolo, F Cheymol, B Bravin, E Raich, U |
author_sort | Roncarolo, F |
collection | CERN |
description | The CERN LINAC4 commissioning will start in 2011, at first in a laboratory test stand where the 45 KeV Hsource is already installed and presently tested, and later in the LINAC4 tunnel. A movable diagnostics bench will be equipped with the necessary sensors capable of characterizing the H- beam in different stages, from 3 MeV up to the first DTL tank at 12 MeV. In this paper we will discuss the accuracy of the transverse emittance measurement that will be performed with the slit-grid method. The system’s mechanical and geometric parameters have been determined in order to achieve the required resolution and sensitivity. Space charge effects during the beam transfer from the slit to the grid and scattering effects at the slit have been considered to determine the overall emittance measurement accuracy. |
id | cern-1303299 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-13032992019-09-30T06:29:59Zhttp://cds.cern.ch/record/1303299engRoncarolo, FCheymol, BBravin, ERaich, UAccuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 MevAccelerators and Storage RingsThe CERN LINAC4 commissioning will start in 2011, at first in a laboratory test stand where the 45 KeV Hsource is already installed and presently tested, and later in the LINAC4 tunnel. A movable diagnostics bench will be equipped with the necessary sensors capable of characterizing the H- beam in different stages, from 3 MeV up to the first DTL tank at 12 MeV. In this paper we will discuss the accuracy of the transverse emittance measurement that will be performed with the slit-grid method. The system’s mechanical and geometric parameters have been determined in order to achieve the required resolution and sensitivity. Space charge effects during the beam transfer from the slit to the grid and scattering effects at the slit have been considered to determine the overall emittance measurement accuracy.CERN-ATS-2010-221oai:cds.cern.ch:13032992010-09-10 |
spellingShingle | Accelerators and Storage Rings Roncarolo, F Cheymol, B Bravin, E Raich, U Accuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 Mev |
title | Accuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 Mev |
title_full | Accuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 Mev |
title_fullStr | Accuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 Mev |
title_full_unstemmed | Accuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 Mev |
title_short | Accuracy determination of the CERN Linac4 emittance measurements at the test bench for 3 and 12 Mev |
title_sort | accuracy determination of the cern linac4 emittance measurements at the test bench for 3 and 12 mev |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1303299 |
work_keys_str_mv | AT roncarolof accuracydeterminationofthecernlinac4emittancemeasurementsatthetestbenchfor3and12mev AT cheymolb accuracydeterminationofthecernlinac4emittancemeasurementsatthetestbenchfor3and12mev AT bravine accuracydeterminationofthecernlinac4emittancemeasurementsatthetestbenchfor3and12mev AT raichu accuracydeterminationofthecernlinac4emittancemeasurementsatthetestbenchfor3and12mev |