Cargando…
Performance of the ATLAS Liquid Argon Calorimeter
The Liquid Argon Calorimeter, as a part of ATLAS detector, is to measure energy of particles produced in the p-p collision at CERN Large Hadron Collider. The system consists of Elctromagnetic Calorimeter(EM), Hadronic End-Cap and Forward Calorimeter. Since its installation completing in 2008, varian...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1304279 |
_version_ | 1780921123707289600 |
---|---|
author | Meng, Z |
author_facet | Meng, Z |
author_sort | Meng, Z |
collection | CERN |
description | The Liquid Argon Calorimeter, as a part of ATLAS detector, is to measure energy of particles produced in the p-p collision at CERN Large Hadron Collider. The system consists of Elctromagnetic Calorimeter(EM), Hadronic End-Cap and Forward Calorimeter. Since its installation completing in 2008, variant performance studies are made using cosmic data, single beam data as well as collision data both at 900GeV and 7TeV. After careful studies, we conclude that the Liquid Argon Calorimeter performance matches its design parameters. This paper is showing the robust studies on it performance. |
id | cern-1304279 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-13042792019-09-30T06:29:59Zhttp://cds.cern.ch/record/1304279engMeng, ZPerformance of the ATLAS Liquid Argon CalorimeterDetectors and Experimental TechniquesThe Liquid Argon Calorimeter, as a part of ATLAS detector, is to measure energy of particles produced in the p-p collision at CERN Large Hadron Collider. The system consists of Elctromagnetic Calorimeter(EM), Hadronic End-Cap and Forward Calorimeter. Since its installation completing in 2008, variant performance studies are made using cosmic data, single beam data as well as collision data both at 900GeV and 7TeV. After careful studies, we conclude that the Liquid Argon Calorimeter performance matches its design parameters. This paper is showing the robust studies on it performance.ATL-LARG-PROC-2010-017oai:cds.cern.ch:13042792010-11-02 |
spellingShingle | Detectors and Experimental Techniques Meng, Z Performance of the ATLAS Liquid Argon Calorimeter |
title | Performance of the ATLAS Liquid Argon Calorimeter |
title_full | Performance of the ATLAS Liquid Argon Calorimeter |
title_fullStr | Performance of the ATLAS Liquid Argon Calorimeter |
title_full_unstemmed | Performance of the ATLAS Liquid Argon Calorimeter |
title_short | Performance of the ATLAS Liquid Argon Calorimeter |
title_sort | performance of the atlas liquid argon calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1304279 |
work_keys_str_mv | AT mengz performanceoftheatlasliquidargoncalorimeter |