Cargando…
Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory
We present preliminary results of beam diagnostics for the world's first Non-Scaling FFAG Accelerator 'EMMA'. Amongst other means, a single-shot/turn-by-turn BPM system is used, that was first tested on the ALICE injector. The BPM system utilizes a front-end conve...
Autores principales: | , |
---|---|
Formato: | info:eu-repo/semantics/article |
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1306182 |
_version_ | 1780921151003820032 |
---|---|
author | Kalinin, A Smith, R |
author_facet | Kalinin, A Smith, R |
author_sort | Kalinin, A |
collection | CERN |
description | We present preliminary results of beam diagnostics for the world's first Non-Scaling FFAG Accelerator 'EMMA'. Amongst other means, a single-shot/turn-by-turn BPM system is used, that was first tested on the ALICE injector. The BPM system utilizes a front-end conversion of button pickup signals into flat-top-envelope 700 MHz bursts, time-domain multiplexing (in each plane, signals are made spaced by 13.8 ns), and the manufacture of both synchronous detector and ADC clocks directly from the beam signal. The system performance is discussed; results of beam-based resolution measurement are given. First turn beam trajectories furthest from the Septum and Kicker are presented. |
format | info:eu-repo/semantics/article |
id | cern-1306182 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-13061822019-09-30T06:29:59Z http://cds.cern.ch/record/1306182 eng Kalinin, A Smith, R Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory Accelerators and Storage Rings 11: Assessment of Novel Accelerator Concepts We present preliminary results of beam diagnostics for the world's first Non-Scaling FFAG Accelerator 'EMMA'. Amongst other means, a single-shot/turn-by-turn BPM system is used, that was first tested on the ALICE injector. The BPM system utilizes a front-end conversion of button pickup signals into flat-top-envelope 700 MHz bursts, time-domain multiplexing (in each plane, signals are made spaced by 13.8 ns), and the manufacture of both synchronous detector and ADC clocks directly from the beam signal. The system performance is discussed; results of beam-based resolution measurement are given. First turn beam trajectories furthest from the Septum and Kicker are presented. info:eu-repo/grantAgreement/EC/FP7/227579 info:eu-repo/semantics/openAccess Education Level info:eu-repo/semantics/article http://cds.cern.ch/record/1306182 2010 |
spellingShingle | Accelerators and Storage Rings 11: Assessment of Novel Accelerator Concepts Kalinin, A Smith, R Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory |
title | Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory |
title_full | Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory |
title_fullStr | Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory |
title_full_unstemmed | Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory |
title_short | Diagnostic System Commissioning of the EMMA NS-FFAG Facility at Daresbury Laboratory |
title_sort | diagnostic system commissioning of the emma ns-ffag facility at daresbury laboratory |
topic | Accelerators and Storage Rings 11: Assessment of Novel Accelerator Concepts |
url | http://cds.cern.ch/record/1306182 http://cds.cern.ch/record/1306182 |
work_keys_str_mv | AT kalinina diagnosticsystemcommissioningoftheemmansffagfacilityatdaresburylaboratory AT smithr diagnosticsystemcommissioningoftheemmansffagfacilityatdaresburylaboratory |