Cargando…

Calibration of the Nonlinear Accelerator Model at the Diamond Storage Ring

The correct implementation of the nonlinear ring model is crucial to achieve the top performance of a synchrotron light source. Several dynamics quantities can be used to compare the real machine with the model and eventually to correct the accelerator. Most of these methods are based on the analysi...

Descripción completa

Detalles Bibliográficos
Autores principales: Bartolini, Riccardo, Rehm, Guenther, Rowland, James, Martin, Ian, Schmidt, Frank
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:http://cds.cern.ch/record/1310800
_version_ 1780921240157945856
author Bartolini, Riccardo
Rehm, Guenther
Rowland, James
Martin, Ian
Schmidt, Frank
author_facet Bartolini, Riccardo
Rehm, Guenther
Rowland, James
Martin, Ian
Schmidt, Frank
author_sort Bartolini, Riccardo
collection CERN
description The correct implementation of the nonlinear ring model is crucial to achieve the top performance of a synchrotron light source. Several dynamics quantities can be used to compare the real machine with the model and eventually to correct the accelerator. Most of these methods are based on the analysis of turn-by-turn data of excited betatron oscillations. We present the experimental results of the campaign of measurements carried out at the Diamond. A combination of Frequency Map Analysis (FMA) and detuning with momentum measurements has allowed a precise calibration of the nonlinear model capable of reproducing the nonlinear beam dynamics in the storage ring
id cern-1310800
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-13108002022-08-17T13:24:26Zhttp://cds.cern.ch/record/1310800engBartolini, RiccardoRehm, GuentherRowland, JamesMartin, IanSchmidt, FrankCalibration of the Nonlinear Accelerator Model at the Diamond Storage RingAccelerators and Storage RingsThe correct implementation of the nonlinear ring model is crucial to achieve the top performance of a synchrotron light source. Several dynamics quantities can be used to compare the real machine with the model and eventually to correct the accelerator. Most of these methods are based on the analysis of turn-by-turn data of excited betatron oscillations. We present the experimental results of the campaign of measurements carried out at the Diamond. A combination of Frequency Map Analysis (FMA) and detuning with momentum measurements has allowed a precise calibration of the nonlinear model capable of reproducing the nonlinear beam dynamics in the storage ringoai:cds.cern.ch:13108002010
spellingShingle Accelerators and Storage Rings
Bartolini, Riccardo
Rehm, Guenther
Rowland, James
Martin, Ian
Schmidt, Frank
Calibration of the Nonlinear Accelerator Model at the Diamond Storage Ring
title Calibration of the Nonlinear Accelerator Model at the Diamond Storage Ring
title_full Calibration of the Nonlinear Accelerator Model at the Diamond Storage Ring
title_fullStr Calibration of the Nonlinear Accelerator Model at the Diamond Storage Ring
title_full_unstemmed Calibration of the Nonlinear Accelerator Model at the Diamond Storage Ring
title_short Calibration of the Nonlinear Accelerator Model at the Diamond Storage Ring
title_sort calibration of the nonlinear accelerator model at the diamond storage ring
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1310800
work_keys_str_mv AT bartoliniriccardo calibrationofthenonlinearacceleratormodelatthediamondstoragering
AT rehmguenther calibrationofthenonlinearacceleratormodelatthediamondstoragering
AT rowlandjames calibrationofthenonlinearacceleratormodelatthediamondstoragering
AT martinian calibrationofthenonlinearacceleratormodelatthediamondstoragering
AT schmidtfrank calibrationofthenonlinearacceleratormodelatthediamondstoragering