Cargando…
Study of gas purifiers for the CMS RPC detector
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RP...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2010.08.089 http://cds.cern.ch/record/1317995 |
_version_ | 1780921420068421632 |
---|---|
author | Benussi, L. Bianco, S. Colafranceschi, S. Fabbri, F.L. Felli, F. Ferrini, M. Giardoni, M. Greci, T. Paolozzi, A. Passamonti, L. Piccolo, D. Pierluigi, D. Russo, A. Saviano, G. Buontempo, S. Cimmino, A. de Gruttola, M. Fabozzi, F. Iorio, A.O.M. Lista, L. Paolucci, P. Baesso, P. Belli, G. Pagano, D. Ratti, S.P. Vicini, A. Vitulo, P. Viviani, C. Guida, R. Sharma, A. |
author_facet | Benussi, L. Bianco, S. Colafranceschi, S. Fabbri, F.L. Felli, F. Ferrini, M. Giardoni, M. Greci, T. Paolozzi, A. Passamonti, L. Piccolo, D. Pierluigi, D. Russo, A. Saviano, G. Buontempo, S. Cimmino, A. de Gruttola, M. Fabozzi, F. Iorio, A.O.M. Lista, L. Paolucci, P. Baesso, P. Belli, G. Pagano, D. Ratti, S.P. Vicini, A. Vitulo, P. Viviani, C. Guida, R. Sharma, A. |
author_sort | Benussi, L. |
collection | CERN |
description | The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported. |
id | cern-1317995 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-13179952019-09-30T06:29:59Zdoi:10.1016/j.nima.2010.08.089http://cds.cern.ch/record/1317995engBenussi, L.Bianco, S.Colafranceschi, S.Fabbri, F.L.Felli, F.Ferrini, M.Giardoni, M.Greci, T.Paolozzi, A.Passamonti, L.Piccolo, D.Pierluigi, D.Russo, A.Saviano, G.Buontempo, S.Cimmino, A.de Gruttola, M.Fabozzi, F.Iorio, A.O.M.Lista, L.Paolucci, P.Baesso, P.Belli, G.Pagano, D.Ratti, S.P.Vicini, A.Vitulo, P.Viviani, C.Guida, R.Sharma, A.Study of gas purifiers for the CMS RPC detectorDetectors and Experimental TechniquesThe CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported.The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported.arXiv:1012.5511oai:cds.cern.ch:13179952010-12-30 |
spellingShingle | Detectors and Experimental Techniques Benussi, L. Bianco, S. Colafranceschi, S. Fabbri, F.L. Felli, F. Ferrini, M. Giardoni, M. Greci, T. Paolozzi, A. Passamonti, L. Piccolo, D. Pierluigi, D. Russo, A. Saviano, G. Buontempo, S. Cimmino, A. de Gruttola, M. Fabozzi, F. Iorio, A.O.M. Lista, L. Paolucci, P. Baesso, P. Belli, G. Pagano, D. Ratti, S.P. Vicini, A. Vitulo, P. Viviani, C. Guida, R. Sharma, A. Study of gas purifiers for the CMS RPC detector |
title | Study of gas purifiers for the CMS RPC detector |
title_full | Study of gas purifiers for the CMS RPC detector |
title_fullStr | Study of gas purifiers for the CMS RPC detector |
title_full_unstemmed | Study of gas purifiers for the CMS RPC detector |
title_short | Study of gas purifiers for the CMS RPC detector |
title_sort | study of gas purifiers for the cms rpc detector |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2010.08.089 http://cds.cern.ch/record/1317995 |
work_keys_str_mv | AT benussil studyofgaspurifiersforthecmsrpcdetector AT biancos studyofgaspurifiersforthecmsrpcdetector AT colafranceschis studyofgaspurifiersforthecmsrpcdetector AT fabbrifl studyofgaspurifiersforthecmsrpcdetector AT fellif studyofgaspurifiersforthecmsrpcdetector AT ferrinim studyofgaspurifiersforthecmsrpcdetector AT giardonim studyofgaspurifiersforthecmsrpcdetector AT grecit studyofgaspurifiersforthecmsrpcdetector AT paolozzia studyofgaspurifiersforthecmsrpcdetector AT passamontil studyofgaspurifiersforthecmsrpcdetector AT piccolod studyofgaspurifiersforthecmsrpcdetector AT pierluigid studyofgaspurifiersforthecmsrpcdetector AT russoa studyofgaspurifiersforthecmsrpcdetector AT savianog studyofgaspurifiersforthecmsrpcdetector AT buontempos studyofgaspurifiersforthecmsrpcdetector AT cimminoa studyofgaspurifiersforthecmsrpcdetector AT degruttolam studyofgaspurifiersforthecmsrpcdetector AT fabozzif studyofgaspurifiersforthecmsrpcdetector AT iorioaom studyofgaspurifiersforthecmsrpcdetector AT listal studyofgaspurifiersforthecmsrpcdetector AT paoluccip studyofgaspurifiersforthecmsrpcdetector AT baessop studyofgaspurifiersforthecmsrpcdetector AT bellig studyofgaspurifiersforthecmsrpcdetector AT paganod studyofgaspurifiersforthecmsrpcdetector AT rattisp studyofgaspurifiersforthecmsrpcdetector AT vicinia studyofgaspurifiersforthecmsrpcdetector AT vitulop studyofgaspurifiersforthecmsrpcdetector AT vivianic studyofgaspurifiersforthecmsrpcdetector AT guidar studyofgaspurifiersforthecmsrpcdetector AT sharmaa studyofgaspurifiersforthecmsrpcdetector |