Cargando…
Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy
A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measuremen...
Autores principales: | , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2010.12.145 http://cds.cern.ch/record/1322287 |
_version_ | 1780921573707874304 |
---|---|
author | Krieger, A. Geppert, Ch. Catherall, R. Hochschulz, F. Kramer, J. Neugart, R. Rosendahl, S. Schipper, J. Siesling, E. Weinheimer, Ch. Yordanov, D.T. Nortershauser, W. |
author_facet | Krieger, A. Geppert, Ch. Catherall, R. Hochschulz, F. Kramer, J. Neugart, R. Rosendahl, S. Schipper, J. Siesling, E. Weinheimer, Ch. Yordanov, D.T. Nortershauser, W. |
author_sort | Krieger, A. |
collection | CERN |
description | A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were investigated for the different power supplies currently applied at ISOLDE. |
id | cern-1322287 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-13222872019-09-30T06:29:59Zdoi:10.1016/j.nima.2010.12.145http://cds.cern.ch/record/1322287engKrieger, A.Geppert, Ch.Catherall, R.Hochschulz, F.Kramer, J.Neugart, R.Rosendahl, S.Schipper, J.Siesling, E.Weinheimer, Ch.Yordanov, D.T.Nortershauser, W.Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopyDetectors and Experimental TechniquesOther Fields of PhysicsA high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were investigated for the different power supplies currently applied at ISOLDE.A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were investigated for the different power supplies currently applied at ISOLDE.arXiv:1101.2536oai:cds.cern.ch:13222872011-01-14 |
spellingShingle | Detectors and Experimental Techniques Other Fields of Physics Krieger, A. Geppert, Ch. Catherall, R. Hochschulz, F. Kramer, J. Neugart, R. Rosendahl, S. Schipper, J. Siesling, E. Weinheimer, Ch. Yordanov, D.T. Nortershauser, W. Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy |
title | Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy |
title_full | Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy |
title_fullStr | Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy |
title_full_unstemmed | Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy |
title_short | Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy |
title_sort | calibration of the isolde acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy |
topic | Detectors and Experimental Techniques Other Fields of Physics |
url | https://dx.doi.org/10.1016/j.nima.2010.12.145 http://cds.cern.ch/record/1322287 |
work_keys_str_mv | AT kriegera calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT geppertch calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT catherallr calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT hochschulzf calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT kramerj calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT neugartr calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT rosendahls calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT schipperj calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT sieslinge calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT weinheimerch calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT yordanovdt calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy AT nortershauserw calibrationoftheisoldeaccelerationvoltageusingahighprecisionvoltagedividerandapplyingcollinearfastbeamlaserspectroscopy |