Cargando…

Dielectric insulation and high-voltage issues

Electrical faults are in most cases dramatic events for magnets, due to the large stored energy which is potentially available to be dissipated at the fault location. After a reminder of the principles of electrostatics in Section 1, the basic mechanisms of conduction and breakdown in dielectrics ar...

Descripción completa

Detalles Bibliográficos
Autor principal: Tommasini, D.
Lenguaje:eng
Publicado: CERN 2011
Materias:
Acceso en línea:https://dx.doi.org/10.5170/CERN-2010-004.335
http://cds.cern.ch/record/1342701
Descripción
Sumario:Electrical faults are in most cases dramatic events for magnets, due to the large stored energy which is potentially available to be dissipated at the fault location. After a reminder of the principles of electrostatics in Section 1, the basic mechanisms of conduction and breakdown in dielectrics are summarized in Section 2. Section 3 introduces the types and function of the electrical insulation in magnets, and Section 4 its relevant failure mechanisms. Section 5 deals with ageing and, finally, Section 6 gives some principles for testing. Though the School specifically dealt with warm magnets, for completeness some principles of dielectric insulation for superconducting accelerator magnets are briefly summarized in a dedicated appendix.