Cargando…
Probability of burn-through of defective 13 kA splices at increased energy levels
In many 13 kA splices in the machine there is a lack of bonding between the superconducting cable and the stabilising copper along with a bad contact between the bus stabiliser and the splice stabiliser. In case of a quench of such a defective splice, the current cannot bypass the cable through the...
Autor principal: | Verweij, A |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2011-005.149 http://cds.cern.ch/record/1353848 |
Ejemplares similares
Ejemplares similares
-
Consolidation of the 13 kA Splices in the Electrical Feedboxes of the LHC
por: Perin, A, et al.
Publicado: (2012) -
Thermal Runaway of the 13 kA Busbar Joints in the LHC
por: Verweij, A P
Publicado: (2010) -
An Improved Insulation System for the LHC Main 13 kA Interconnection Splices
por: Lackner, F, et al.
Publicado: (2013) -
Electro-thermal FEM simulations of the 13-kA LHC joints
por: Molnar, D, et al.
Publicado: (2013) -
Analysis of Defective Interconnections of the 13 kA LHC Superconducting Bus Bars
por: Granieri, P P, et al.
Publicado: (2012)