Cargando…
EURISOL-DS Overall Design of the Multi-MW Target Station
The EURISOL Design Study investigated the feasibility of a complex instrument to push back the boundaries of current physics knowledge amidst today’s ever-increasing need for realism due to constraints imposed by safety, performance and, not least, budgetary responsibility.In order to attend to thes...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
03/0
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1355046 |
_version_ | 1780922408425750528 |
---|---|
author | Olivier Choisnet, Cyril Kharoua, Yacine Kadi, Karel Samec (CERN) |
author_facet | Olivier Choisnet, Cyril Kharoua, Yacine Kadi, Karel Samec (CERN) |
author_sort | Olivier Choisnet, Cyril Kharoua, Yacine Kadi, Karel Samec (CERN) |
collection | CERN |
description | The EURISOL Design Study investigated the feasibility of a complex instrument to push back the boundaries of current physics knowledge amidst today’s ever-increasing need for realism due to constraints imposed by safety, performance and, not least, budgetary responsibility.In order to attend to these concerns, the EURISOL Multi-Megawatt converter target, its associated fission targets and the three 100 kW direct targets are all integrated into a single facility housing the ancillary equipment as well. The overall layout of the facility, its functional break-down and the main modes of operation are presented in the current report. |
id | cern-1355046 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 03/0 |
record_format | invenio |
spelling | cern-13550462019-09-30T06:29:59Zhttp://cds.cern.ch/record/1355046engOlivier Choisnet, Cyril Kharoua, Yacine Kadi, Karel Samec (CERN)EURISOL-DS Overall Design of the Multi-MW Target Station2: TASK 2The EURISOL Design Study investigated the feasibility of a complex instrument to push back the boundaries of current physics knowledge amidst today’s ever-increasing need for realism due to constraints imposed by safety, performance and, not least, budgetary responsibility.In order to attend to these concerns, the EURISOL Multi-Megawatt converter target, its associated fission targets and the three 100 kW direct targets are all integrated into a single facility housing the ancillary equipment as well. The overall layout of the facility, its functional break-down and the main modes of operation are presented in the current report.EURISOL-02-25-2009-0046oai:cds.cern.ch:135504603/09/09 |
spellingShingle | 2: TASK 2 Olivier Choisnet, Cyril Kharoua, Yacine Kadi, Karel Samec (CERN) EURISOL-DS Overall Design of the Multi-MW Target Station |
title | EURISOL-DS Overall Design of the Multi-MW Target Station |
title_full | EURISOL-DS Overall Design of the Multi-MW Target Station |
title_fullStr | EURISOL-DS Overall Design of the Multi-MW Target Station |
title_full_unstemmed | EURISOL-DS Overall Design of the Multi-MW Target Station |
title_short | EURISOL-DS Overall Design of the Multi-MW Target Station |
title_sort | eurisol-ds overall design of the multi-mw target station |
topic | 2: TASK 2 |
url | http://cds.cern.ch/record/1355046 |
work_keys_str_mv | AT olivierchoisnetcyrilkharouayacinekadikarelsameccern eurisoldsoveralldesignofthemultimwtargetstation |