Cargando…

EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET

The analysis of the EURISOL-DS Multi_MW target precise geometry (Fig.1) has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which ma...

Descripción completa

Detalles Bibliográficos
Autor principal: Adonai Herrera-Martínez, Yacine Kadi
Lenguaje:eng
Publicado: 28/0
Materias:
Acceso en línea:http://cds.cern.ch/record/1355095
_version_ 1780922416256516096
author Adonai Herrera-Martínez, Yacine Kadi
author_facet Adonai Herrera-Martínez, Yacine Kadi
author_sort Adonai Herrera-Martínez, Yacine Kadi
collection CERN
description The analysis of the EURISOL-DS Multi_MW target precise geometry (Fig.1) has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which maintain its temperature below the boiling point with moderate flow speeds (maximum 4 m/s).
id cern-1355095
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 28/0
record_format invenio
spelling cern-13550952019-09-30T06:29:59Zhttp://cds.cern.ch/record/1355095engAdonai Herrera-Martínez, Yacine KadiEURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET4: TASK 4The analysis of the EURISOL-DS Multi_MW target precise geometry (Fig.1) has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which maintain its temperature below the boiling point with moderate flow speeds (maximum 4 m/s).EURISOL-04-25-2007-0004oai:cds.cern.ch:135509528/02/07
spellingShingle 4: TASK 4
Adonai Herrera-Martínez, Yacine Kadi
EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET
title EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET
title_full EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET
title_fullStr EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET
title_full_unstemmed EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET
title_short EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET
title_sort eurisol-ds multi-mw target issues: beam window and transverse film target
topic 4: TASK 4
url http://cds.cern.ch/record/1355095
work_keys_str_mv AT adonaiherreramartinezyacinekadi eurisoldsmultimwtargetissuesbeamwindowandtransversefilmtarget