Cargando…
EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET
The analysis of the EURISOL-DS Multi_MW target precise geometry (Fig.1) has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which ma...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
28/0
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1355095 |
_version_ | 1780922416256516096 |
---|---|
author | Adonai Herrera-Martínez, Yacine Kadi |
author_facet | Adonai Herrera-Martínez, Yacine Kadi |
author_sort | Adonai Herrera-Martínez, Yacine Kadi |
collection | CERN |
description | The analysis of the EURISOL-DS Multi_MW target precise geometry (Fig.1) has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which maintain its temperature below the boiling point with moderate flow speeds (maximum 4 m/s). |
id | cern-1355095 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 28/0 |
record_format | invenio |
spelling | cern-13550952019-09-30T06:29:59Zhttp://cds.cern.ch/record/1355095engAdonai Herrera-Martínez, Yacine KadiEURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET4: TASK 4The analysis of the EURISOL-DS Multi_MW target precise geometry (Fig.1) has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which maintain its temperature below the boiling point with moderate flow speeds (maximum 4 m/s).EURISOL-04-25-2007-0004oai:cds.cern.ch:135509528/02/07 |
spellingShingle | 4: TASK 4 Adonai Herrera-Martínez, Yacine Kadi EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET |
title | EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET |
title_full | EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET |
title_fullStr | EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET |
title_full_unstemmed | EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET |
title_short | EURISOL-DS MULTI-MW TARGET ISSUES: BEAM WINDOW AND TRANSVERSE FILM TARGET |
title_sort | eurisol-ds multi-mw target issues: beam window and transverse film target |
topic | 4: TASK 4 |
url | http://cds.cern.ch/record/1355095 |
work_keys_str_mv | AT adonaiherreramartinezyacinekadi eurisoldsmultimwtargetissuesbeamwindowandtransversefilmtarget |