Cargando…

Multi-MW target station: Beam Window Issues and Transverse Film Target

The analysis of the EURISOL-DS Multi_MW target precise geometry has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which maintain i...

Descripción completa

Detalles Bibliográficos
Autores principales: Herrera-Martinez, A, Kadi, Y
Lenguaje:eng
Publicado: 08/0
Materias:
Acceso en línea:http://cds.cern.ch/record/1356469
_version_ 1780922477090701312
author Herrera-Martinez, A
Kadi, Y
author_facet Herrera-Martinez, A
Kadi, Y
author_sort Herrera-Martinez, A
collection CERN
description The analysis of the EURISOL-DS Multi_MW target precise geometry has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which maintain its temperature below the boiling point with moderate flow speeds (maximum 4 m/s).
id cern-1356469
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 08/0
record_format invenio
spelling cern-13564692019-09-30T06:29:59Zhttp://cds.cern.ch/record/1356469engHerrera-Martinez, AKadi, YMulti-MW target station: Beam Window Issues and Transverse Film Target2: TASK 2The analysis of the EURISOL-DS Multi_MW target precise geometry has proved that large fission yields can be achieved with a 4 MW, providing a technically feasible design to evacuate the power deposited in the liquid mercury. Different designs for the mercury flow have been proposed, which maintain its temperature below the boiling point with moderate flow speeds (maximum 4 m/s).EURISOL-02-25-2007-0012oai:cds.cern.ch:135646908/02/07
spellingShingle 2: TASK 2
Herrera-Martinez, A
Kadi, Y
Multi-MW target station: Beam Window Issues and Transverse Film Target
title Multi-MW target station: Beam Window Issues and Transverse Film Target
title_full Multi-MW target station: Beam Window Issues and Transverse Film Target
title_fullStr Multi-MW target station: Beam Window Issues and Transverse Film Target
title_full_unstemmed Multi-MW target station: Beam Window Issues and Transverse Film Target
title_short Multi-MW target station: Beam Window Issues and Transverse Film Target
title_sort multi-mw target station: beam window issues and transverse film target
topic 2: TASK 2
url http://cds.cern.ch/record/1356469
work_keys_str_mv AT herreramartineza multimwtargetstationbeamwindowissuesandtransversefilmtarget
AT kadiy multimwtargetstationbeamwindowissuesandtransversefilmtarget