Test Results from Quality Control Measurements of Phototubes for the CMS-CASTOR Calorimeter
The CMS CASTOR calorimeter will be equipped with $224$ photomultiplier tubes (PMTs) in order to detect the Cherenkov light produced by the relativistic charged particles. Before the installation in the calorimeter these PMTs have to be verified for having sufficiently good performance. We constructe...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2008
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1358695 |
_version_ | 1780922561850245120 |
---|---|
author | Aydin, Sezgin Dumanoglu, Isa Onengut, Gulsen Ozturk, Sertac Sogut, Kenan |
author_facet | Aydin, Sezgin Dumanoglu, Isa Onengut, Gulsen Ozturk, Sertac Sogut, Kenan |
author_sort | Aydin, Sezgin |
collection | CERN |
description | The CMS CASTOR calorimeter will be equipped with $224$ photomultiplier tubes (PMTs) in order to detect the Cherenkov light produced by the relativistic charged particles. Before the installation in the calorimeter these PMTs have to be verified for having sufficiently good performance. We constructed two different systems to make certain that PMTs have the required operational criteria to be used in the calorimeter. This paper details the CASTOR calorimeter, PMT testing systems,testing procedure and gives the results of the measurements. |
id | cern-1358695 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2008 |
record_format | invenio |
spelling | cern-13586952019-09-30T06:29:59Zhttp://cds.cern.ch/record/1358695engAydin, SezginDumanoglu, IsaOnengut, GulsenOzturk, SertacSogut, KenanTest Results from Quality Control Measurements of Phototubes for the CMS-CASTOR CalorimeterDetectors and Experimental TechniquesThe CMS CASTOR calorimeter will be equipped with $224$ photomultiplier tubes (PMTs) in order to detect the Cherenkov light produced by the relativistic charged particles. Before the installation in the calorimeter these PMTs have to be verified for having sufficiently good performance. We constructed two different systems to make certain that PMTs have the required operational criteria to be used in the calorimeter. This paper details the CASTOR calorimeter, PMT testing systems,testing procedure and gives the results of the measurements.CMS-CR-2007-083oai:cds.cern.ch:13586952008-04-03 |
spellingShingle | Detectors and Experimental Techniques Aydin, Sezgin Dumanoglu, Isa Onengut, Gulsen Ozturk, Sertac Sogut, Kenan Test Results from Quality Control Measurements of Phototubes for the CMS-CASTOR Calorimeter |
title | Test Results from Quality Control Measurements of Phototubes for the CMS-CASTOR Calorimeter |
title_full | Test Results from Quality Control Measurements of Phototubes for the CMS-CASTOR Calorimeter |
title_fullStr | Test Results from Quality Control Measurements of Phototubes for the CMS-CASTOR Calorimeter |
title_full_unstemmed | Test Results from Quality Control Measurements of Phototubes for the CMS-CASTOR Calorimeter |
title_short | Test Results from Quality Control Measurements of Phototubes for the CMS-CASTOR Calorimeter |
title_sort | test results from quality control measurements of phototubes for the cms-castor calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/1358695 |
work_keys_str_mv | AT aydinsezgin testresultsfromqualitycontrolmeasurementsofphototubesforthecmscastorcalorimeter AT dumanogluisa testresultsfromqualitycontrolmeasurementsofphototubesforthecmscastorcalorimeter AT onengutgulsen testresultsfromqualitycontrolmeasurementsofphototubesforthecmscastorcalorimeter AT ozturksertac testresultsfromqualitycontrolmeasurementsofphototubesforthecmscastorcalorimeter AT sogutkenan testresultsfromqualitycontrolmeasurementsofphototubesforthecmscastorcalorimeter |