Design of the CMS-CASTOR sub detector readout system by reusing existing designs

CASTOR is a cylindrical calorimeter with a length of 1.5m and a diameter of 60cm located at 14.3 meters from the CMS interaction point and covering the range in pseudo-rapidity corresponding to 5.1 ~\textless~ \textbar~ eta~ \textbar ~ \textless ~ 6.6. The CASTOR project was approved in the middle...

Descripción completa

Detalles Bibliográficos
Autor principal: Beaumont, Willem
Lenguaje:eng
Publicado: 2009
Materias:
Acceso en línea:http://cds.cern.ch/record/1358826
_version_ 1780922582753607680
author Beaumont, Willem
author_facet Beaumont, Willem
author_sort Beaumont, Willem
collection CERN
description CASTOR is a cylindrical calorimeter with a length of 1.5m and a diameter of 60cm located at 14.3 meters from the CMS interaction point and covering the range in pseudo-rapidity corresponding to 5.1 ~\textless~ \textbar~ eta~ \textbar ~ \textless ~ 6.6. The CASTOR project was approved in the middle of 2007. Given the limited resources and time, developing a readout system from scratch was excluded. Here the final implementations of the readout chain, the considerations for the different choices as well as the performance of the installed equipment are discussed.
id cern-1358826
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2009
record_format invenio
spelling cern-13588262019-09-30T06:29:59Zhttp://cds.cern.ch/record/1358826engBeaumont, WillemDesign of the CMS-CASTOR sub detector readout system by reusing existing designsDetectors and Experimental TechniquesCASTOR is a cylindrical calorimeter with a length of 1.5m and a diameter of 60cm located at 14.3 meters from the CMS interaction point and covering the range in pseudo-rapidity corresponding to 5.1 ~\textless~ \textbar~ eta~ \textbar ~ \textless ~ 6.6. The CASTOR project was approved in the middle of 2007. Given the limited resources and time, developing a readout system from scratch was excluded. Here the final implementations of the readout chain, the considerations for the different choices as well as the performance of the installed equipment are discussed.CMS-CR-2009-324oai:cds.cern.ch:13588262009-10-19
spellingShingle Detectors and Experimental Techniques
Beaumont, Willem
Design of the CMS-CASTOR sub detector readout system by reusing existing designs
title Design of the CMS-CASTOR sub detector readout system by reusing existing designs
title_full Design of the CMS-CASTOR sub detector readout system by reusing existing designs
title_fullStr Design of the CMS-CASTOR sub detector readout system by reusing existing designs
title_full_unstemmed Design of the CMS-CASTOR sub detector readout system by reusing existing designs
title_short Design of the CMS-CASTOR sub detector readout system by reusing existing designs
title_sort design of the cms-castor sub detector readout system by reusing existing designs
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/1358826
work_keys_str_mv AT beaumontwillem designofthecmscastorsubdetectorreadoutsystembyreusingexistingdesigns