Cargando…
Radiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence Monitoring
Aiming at evaluating new options for radiation monitoring sensors in LHC/SLHC experiments, the radiation responses of FZ and MCz custom made silicon detectors of different geometry have been studied up to about 4 x 10(14) n(eq)/cm(2). The radiation response of the devices under investigation is disc...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2010.2077652 http://cds.cern.ch/record/1359268 |
_version_ | 1780922617440501760 |
---|---|
author | Mekki, J Moll, Michael Dusseau, Laurent Roche, Nicolas Jean-Henri Saigne, Frederic Mekki, Julien Glaser, Maurice |
author_facet | Mekki, J Moll, Michael Dusseau, Laurent Roche, Nicolas Jean-Henri Saigne, Frederic Mekki, Julien Glaser, Maurice |
author_sort | Mekki, J |
collection | CERN |
description | Aiming at evaluating new options for radiation monitoring sensors in LHC/SLHC experiments, the radiation responses of FZ and MCz custom made silicon detectors of different geometry have been studied up to about 4 x 10(14) n(eq)/cm(2). The radiation response of the devices under investigation is discussed in terms of material type, thickness and active area influence. |
id | cern-1359268 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-13592682019-09-30T06:29:59Zdoi:10.1109/TNS.2010.2077652http://cds.cern.ch/record/1359268engMekki, JMoll, MichaelDusseau, LaurentRoche, Nicolas Jean-HenriSaigne, FredericMekki, JulienGlaser, MauriceRadiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence MonitoringDetectors and Experimental TechniquesAiming at evaluating new options for radiation monitoring sensors in LHC/SLHC experiments, the radiation responses of FZ and MCz custom made silicon detectors of different geometry have been studied up to about 4 x 10(14) n(eq)/cm(2). The radiation response of the devices under investigation is discussed in terms of material type, thickness and active area influence.oai:cds.cern.ch:13592682010 |
spellingShingle | Detectors and Experimental Techniques Mekki, J Moll, Michael Dusseau, Laurent Roche, Nicolas Jean-Henri Saigne, Frederic Mekki, Julien Glaser, Maurice Radiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence Monitoring |
title | Radiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence Monitoring |
title_full | Radiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence Monitoring |
title_fullStr | Radiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence Monitoring |
title_full_unstemmed | Radiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence Monitoring |
title_short | Radiation Response of Forward Biased Float Zone and Magnetic Czochralski Silicon Detectors of Different Geometry for 1-MeV Neutron Equivalent Fluence Monitoring |
title_sort | radiation response of forward biased float zone and magnetic czochralski silicon detectors of different geometry for 1-mev neutron equivalent fluence monitoring |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/TNS.2010.2077652 http://cds.cern.ch/record/1359268 |
work_keys_str_mv | AT mekkij radiationresponseofforwardbiasedfloatzoneandmagneticczochralskisilicondetectorsofdifferentgeometryfor1mevneutronequivalentfluencemonitoring AT mollmichael radiationresponseofforwardbiasedfloatzoneandmagneticczochralskisilicondetectorsofdifferentgeometryfor1mevneutronequivalentfluencemonitoring AT dusseaulaurent radiationresponseofforwardbiasedfloatzoneandmagneticczochralskisilicondetectorsofdifferentgeometryfor1mevneutronequivalentfluencemonitoring AT rochenicolasjeanhenri radiationresponseofforwardbiasedfloatzoneandmagneticczochralskisilicondetectorsofdifferentgeometryfor1mevneutronequivalentfluencemonitoring AT saignefrederic radiationresponseofforwardbiasedfloatzoneandmagneticczochralskisilicondetectorsofdifferentgeometryfor1mevneutronequivalentfluencemonitoring AT mekkijulien radiationresponseofforwardbiasedfloatzoneandmagneticczochralskisilicondetectorsofdifferentgeometryfor1mevneutronequivalentfluencemonitoring AT glasermaurice radiationresponseofforwardbiasedfloatzoneandmagneticczochralskisilicondetectorsofdifferentgeometryfor1mevneutronequivalentfluencemonitoring |