Cargando…
Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer
The performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer has been evaluated consistently by using detailed Monte Carlo simulations of the two devices. Results for the multi-nucleon transfer reaction Ca-48+Pb-208 at 310 MeV beam energy are presented and discussed in...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2010
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2010.06.198 http://cds.cern.ch/record/1359305 |
_version_ | 1780922625447428096 |
---|---|
author | Ince, E Pollarolo, G Latina, A Farnea, E Erduran, M N |
author_facet | Ince, E Pollarolo, G Latina, A Farnea, E Erduran, M N |
author_sort | Ince, E |
collection | CERN |
description | The performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer has been evaluated consistently by using detailed Monte Carlo simulations of the two devices. Results for the multi-nucleon transfer reaction Ca-48+Pb-208 at 310 MeV beam energy are presented and discussed in this study. The present results suggest that the Doppler correction capabilities of the AGATA+PRISMA setup will be very close to the intrinsic energy resolution of the germanium detectors. (C) 2010 Elsevier B.V. All rights reserved. |
id | cern-1359305 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2010 |
record_format | invenio |
spelling | cern-13593052019-09-30T06:29:59Zdoi:10.1016/j.nima.2010.06.198http://cds.cern.ch/record/1359305engInce, EPollarolo, GLatina, AFarnea, EErduran, M NRealistic simulations of the AGATA Demonstrator plus PRISMA spectrometerDetectors and Experimental TechniquesThe performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer has been evaluated consistently by using detailed Monte Carlo simulations of the two devices. Results for the multi-nucleon transfer reaction Ca-48+Pb-208 at 310 MeV beam energy are presented and discussed in this study. The present results suggest that the Doppler correction capabilities of the AGATA+PRISMA setup will be very close to the intrinsic energy resolution of the germanium detectors. (C) 2010 Elsevier B.V. All rights reserved.oai:cds.cern.ch:13593052010 |
spellingShingle | Detectors and Experimental Techniques Ince, E Pollarolo, G Latina, A Farnea, E Erduran, M N Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer |
title | Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer |
title_full | Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer |
title_fullStr | Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer |
title_full_unstemmed | Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer |
title_short | Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer |
title_sort | realistic simulations of the agata demonstrator plus prisma spectrometer |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2010.06.198 http://cds.cern.ch/record/1359305 |
work_keys_str_mv | AT incee realisticsimulationsoftheagatademonstratorplusprismaspectrometer AT pollarolog realisticsimulationsoftheagatademonstratorplusprismaspectrometer AT latinaa realisticsimulationsoftheagatademonstratorplusprismaspectrometer AT farneae realisticsimulationsoftheagatademonstratorplusprismaspectrometer AT erduranmn realisticsimulationsoftheagatademonstratorplusprismaspectrometer |