Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer

The performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer has been evaluated consistently by using detailed Monte Carlo simulations of the two devices. Results for the multi-nucleon transfer reaction Ca-48+Pb-208 at 310 MeV beam energy are presented and discussed in...

Descripción completa

Detalles Bibliográficos
Autores principales: Ince, E, Pollarolo, G, Latina, A, Farnea, E, Erduran, M N
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2010.06.198
http://cds.cern.ch/record/1359305
_version_ 1780922625447428096
author Ince, E
Pollarolo, G
Latina, A
Farnea, E
Erduran, M N
author_facet Ince, E
Pollarolo, G
Latina, A
Farnea, E
Erduran, M N
author_sort Ince, E
collection CERN
description The performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer has been evaluated consistently by using detailed Monte Carlo simulations of the two devices. Results for the multi-nucleon transfer reaction Ca-48+Pb-208 at 310 MeV beam energy are presented and discussed in this study. The present results suggest that the Doppler correction capabilities of the AGATA+PRISMA setup will be very close to the intrinsic energy resolution of the germanium detectors. (C) 2010 Elsevier B.V. All rights reserved.
id cern-1359305
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-13593052019-09-30T06:29:59Zdoi:10.1016/j.nima.2010.06.198http://cds.cern.ch/record/1359305engInce, EPollarolo, GLatina, AFarnea, EErduran, M NRealistic simulations of the AGATA Demonstrator plus PRISMA spectrometerDetectors and Experimental TechniquesThe performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer has been evaluated consistently by using detailed Monte Carlo simulations of the two devices. Results for the multi-nucleon transfer reaction Ca-48+Pb-208 at 310 MeV beam energy are presented and discussed in this study. The present results suggest that the Doppler correction capabilities of the AGATA+PRISMA setup will be very close to the intrinsic energy resolution of the germanium detectors. (C) 2010 Elsevier B.V. All rights reserved.oai:cds.cern.ch:13593052010
spellingShingle Detectors and Experimental Techniques
Ince, E
Pollarolo, G
Latina, A
Farnea, E
Erduran, M N
Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer
title Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer
title_full Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer
title_fullStr Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer
title_full_unstemmed Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer
title_short Realistic simulations of the AGATA Demonstrator plus PRISMA spectrometer
title_sort realistic simulations of the agata demonstrator plus prisma spectrometer
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nima.2010.06.198
http://cds.cern.ch/record/1359305
work_keys_str_mv AT incee realisticsimulationsoftheagatademonstratorplusprismaspectrometer
AT pollarolog realisticsimulationsoftheagatademonstratorplusprismaspectrometer
AT latinaa realisticsimulationsoftheagatademonstratorplusprismaspectrometer
AT farneae realisticsimulationsoftheagatademonstratorplusprismaspectrometer
AT erduranmn realisticsimulationsoftheagatademonstratorplusprismaspectrometer