Cargando…

Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy

As carbon ions, at therapeutic energies, penetrate tissue, they undergo inelastic nuclear reactions and give rise to significant yields of secondary fragment fluences. Therefore, an accurate prediction of these fluences resulting from the primary carbon interactions is necessary in the patient'...

Descripción completa

Detalles Bibliográficos
Autores principales: Bohlen, TT, Dosanjh, M, Quesada, J M, Bohlen, T T, Cerutti, F, Gudowska, I, Ferrari, A, Mairani, A
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1088/0031-9155/55/19/014
http://cds.cern.ch/record/1359312
_version_ 1780922626778071040
author Bohlen, TT
Dosanjh, M
Quesada, J M
Bohlen, T T
Cerutti, F
Gudowska, I
Ferrari, A
Mairani, A
author_facet Bohlen, TT
Dosanjh, M
Quesada, J M
Bohlen, T T
Cerutti, F
Gudowska, I
Ferrari, A
Mairani, A
author_sort Bohlen, TT
collection CERN
description As carbon ions, at therapeutic energies, penetrate tissue, they undergo inelastic nuclear reactions and give rise to significant yields of secondary fragment fluences. Therefore, an accurate prediction of these fluences resulting from the primary carbon interactions is necessary in the patient's body in order to precisely simulate the spatial dose distribution and the resulting biological effect. In this paper, the performance of nuclear fragmentation models of the Monte Carlo transport codes, FLUKA and GEANT4, in tissue-like media and for an energy regime relevant for therapeutic carbon ions is investigated. The ability of these Monte Carlo codes to reproduce experimental data of charge-changing cross sections and integral and differential yields of secondary charged fragments is evaluated. For the fragment yields, the main focus is on the consideration of experimental approximations and uncertainties such as the energy measurement by time-of-flight. For GEANT4, the hadronic models G4BinaryLightIonReaction and G4QMD are benchmarked together with some recently enhanced de-excitation models. For non-differential quantities, discrepancies of some tens of percent are found for both codes. For differential quantities, even larger deviations are found. Implications of these findings for the therapeutic use of carbon ions are discussed.
id cern-1359312
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-13593122019-09-30T06:29:59Zdoi:10.1088/0031-9155/55/19/014http://cds.cern.ch/record/1359312engBohlen, TTDosanjh, MQuesada, J MBohlen, T TCerutti, FGudowska, IFerrari, AMairani, ABenchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapyHealth Physics and Radiation EffectsAs carbon ions, at therapeutic energies, penetrate tissue, they undergo inelastic nuclear reactions and give rise to significant yields of secondary fragment fluences. Therefore, an accurate prediction of these fluences resulting from the primary carbon interactions is necessary in the patient's body in order to precisely simulate the spatial dose distribution and the resulting biological effect. In this paper, the performance of nuclear fragmentation models of the Monte Carlo transport codes, FLUKA and GEANT4, in tissue-like media and for an energy regime relevant for therapeutic carbon ions is investigated. The ability of these Monte Carlo codes to reproduce experimental data of charge-changing cross sections and integral and differential yields of secondary charged fragments is evaluated. For the fragment yields, the main focus is on the consideration of experimental approximations and uncertainties such as the energy measurement by time-of-flight. For GEANT4, the hadronic models G4BinaryLightIonReaction and G4QMD are benchmarked together with some recently enhanced de-excitation models. For non-differential quantities, discrepancies of some tens of percent are found for both codes. For differential quantities, even larger deviations are found. Implications of these findings for the therapeutic use of carbon ions are discussed.oai:cds.cern.ch:13593122010
spellingShingle Health Physics and Radiation Effects
Bohlen, TT
Dosanjh, M
Quesada, J M
Bohlen, T T
Cerutti, F
Gudowska, I
Ferrari, A
Mairani, A
Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
title Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
title_full Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
title_fullStr Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
title_full_unstemmed Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
title_short Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy
title_sort benchmarking nuclear models of fluka and geant4 for carbon ion therapy
topic Health Physics and Radiation Effects
url https://dx.doi.org/10.1088/0031-9155/55/19/014
http://cds.cern.ch/record/1359312
work_keys_str_mv AT bohlentt benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy
AT dosanjhm benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy
AT quesadajm benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy
AT bohlentt benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy
AT ceruttif benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy
AT gudowskai benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy
AT ferraria benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy
AT mairania benchmarkingnuclearmodelsofflukaandgeant4forcarboniontherapy