Cargando…

The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study

Scanned ion beam delivery promises superior flexibility and accuracy for highly conformal tumour therapy in comparison to the usage of passive beam shaping systems. The attainable precision demands correct overlapping of the pencil-like beams which build up the entire dose distribution in the treatm...

Descripción completa

Detalles Bibliográficos
Autores principales: Parodi, K, Haberer, T, Kraemer, M, Sommerer, F, Naumann, J, Mairani, A, Brons, S
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1088/0031-9155/55/17/018
http://cds.cern.ch/record/1359317
_version_ 1780922627869638656
author Parodi, K
Haberer, T
Kraemer, M
Sommerer, F
Naumann, J
Mairani, A
Brons, S
author_facet Parodi, K
Haberer, T
Kraemer, M
Sommerer, F
Naumann, J
Mairani, A
Brons, S
author_sort Parodi, K
collection CERN
description Scanned ion beam delivery promises superior flexibility and accuracy for highly conformal tumour therapy in comparison to the usage of passive beam shaping systems. The attainable precision demands correct overlapping of the pencil-like beams which build up the entire dose distribution in the treatment field. In particular, improper dose application due to deviations of the lateral beam profiles from the nominal planning conditions must be prevented via appropriate beam monitoring in the beamline, prior to the entrance in the patient. To assess the necessary tolerance thresholds of the beam monitoring system at the Heidelberg Ion Beam Therapy Center, Germany, this study has investigated several worst-case scenarios for a sensitive treatment plan, namely scanned proton and carbon ion delivery to a small target volume at a shallow depth. Deviations from the nominal lateral beam profiles were simulated, which may occur because of misaligned elements or changes of the beam optic in the beamline. Data have been analysed with respect to the lateral penumbra, homogeneity and coverage of the dose deposition in the target volume. The results indicate that homogeneity is not seriously compromised by extremely narrow profiles for the standard planning choices of the lateral raster scan stepping and dose grid. Differently, broad beam distributions can significantly deteriorate the conformality of the dose delivery and too large increases (above approximate to 150-200\% of the nominal spotsize) must be prevented.
id cern-1359317
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-13593172019-09-30T06:29:59Zdoi:10.1088/0031-9155/55/17/018http://cds.cern.ch/record/1359317engParodi, KHaberer, TKraemer, MSommerer, FNaumann, JMairani, ABrons, SThe influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo studyHealth Physics and Radiation EffectsScanned ion beam delivery promises superior flexibility and accuracy for highly conformal tumour therapy in comparison to the usage of passive beam shaping systems. The attainable precision demands correct overlapping of the pencil-like beams which build up the entire dose distribution in the treatment field. In particular, improper dose application due to deviations of the lateral beam profiles from the nominal planning conditions must be prevented via appropriate beam monitoring in the beamline, prior to the entrance in the patient. To assess the necessary tolerance thresholds of the beam monitoring system at the Heidelberg Ion Beam Therapy Center, Germany, this study has investigated several worst-case scenarios for a sensitive treatment plan, namely scanned proton and carbon ion delivery to a small target volume at a shallow depth. Deviations from the nominal lateral beam profiles were simulated, which may occur because of misaligned elements or changes of the beam optic in the beamline. Data have been analysed with respect to the lateral penumbra, homogeneity and coverage of the dose deposition in the target volume. The results indicate that homogeneity is not seriously compromised by extremely narrow profiles for the standard planning choices of the lateral raster scan stepping and dose grid. Differently, broad beam distributions can significantly deteriorate the conformality of the dose delivery and too large increases (above approximate to 150-200\% of the nominal spotsize) must be prevented.oai:cds.cern.ch:13593172010
spellingShingle Health Physics and Radiation Effects
Parodi, K
Haberer, T
Kraemer, M
Sommerer, F
Naumann, J
Mairani, A
Brons, S
The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study
title The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study
title_full The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study
title_fullStr The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study
title_full_unstemmed The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study
title_short The influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a Monte Carlo study
title_sort influence of lateral beam profile modifications in scanned proton and carbon ion therapy: a monte carlo study
topic Health Physics and Radiation Effects
url https://dx.doi.org/10.1088/0031-9155/55/17/018
http://cds.cern.ch/record/1359317
work_keys_str_mv AT parodik theinfluenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT haberert theinfluenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT kraemerm theinfluenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT sommererf theinfluenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT naumannj theinfluenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT mairania theinfluenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT bronss theinfluenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT parodik influenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT haberert influenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT kraemerm influenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT sommererf influenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT naumannj influenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT mairania influenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy
AT bronss influenceoflateralbeamprofilemodificationsinscannedprotonandcarboniontherapyamontecarlostudy