Cargando…

Analysis of the FIC detector data at the n_TOF facility

Fission cross-section measurements with the Fast Ionization Chamber (FIC) at the CERN n\_TOF facility were challenged by intense signals due to gamma-rays and ultra-relativistic particles from the impact of the 20 GeV proton pulses on the neutron spallation target. A method for analyzing the data ta...

Descripción completa

Detalles Bibliográficos
Autores principales: Karadimos, D, Stamoulis, K, Papachristodoulou, C, Vlachoudis, V, Assimakopoulos, P, Ioannides, K, Vlastou, R, Karamanis, D, Tsagas, N, Cennini, P, Konovalov, V, Ketlerov, V
Lenguaje:eng
Publicado: 2010
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nimb.2010.05.006
http://cds.cern.ch/record/1359320
_version_ 1780922628516610048
author Karadimos, D
Stamoulis, K
Papachristodoulou, C
Vlachoudis, V
Assimakopoulos, P
Ioannides, K
Vlastou, R
Karamanis, D
Tsagas, N
Cennini, P
Konovalov, V
Ketlerov, V
author_facet Karadimos, D
Stamoulis, K
Papachristodoulou, C
Vlachoudis, V
Assimakopoulos, P
Ioannides, K
Vlastou, R
Karamanis, D
Tsagas, N
Cennini, P
Konovalov, V
Ketlerov, V
author_sort Karadimos, D
collection CERN
description Fission cross-section measurements with the Fast Ionization Chamber (FIC) at the CERN n\_TOF facility were challenged by intense signals due to gamma-rays and ultra-relativistic particles from the impact of the 20 GeV proton pulses on the neutron spallation target. A method for analyzing the data taken with Flash Analog to Digital Converters (FADC) was developed to treat these problems in an automated way to provide a reliable background subtraction and a fit routine for identifying fission events even at high energies. The analysis is illustrated at the example of the fission cross-section of U-238 relative to that of U-235 in the energy range from 40 key to 300 MeV. (C) 2010 Elsevier B.V. All rights reserved.
id cern-1359320
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2010
record_format invenio
spelling cern-13593202019-09-30T06:29:59Zdoi:10.1016/j.nimb.2010.05.006http://cds.cern.ch/record/1359320engKaradimos, DStamoulis, KPapachristodoulou, CVlachoudis, VAssimakopoulos, PIoannides, KVlastou, RKaramanis, DTsagas, NCennini, PKonovalov, VKetlerov, VAnalysis of the FIC detector data at the n_TOF facilityNuclear Physics - ExperimentDetectors and Experimental TechniquesFission cross-section measurements with the Fast Ionization Chamber (FIC) at the CERN n\_TOF facility were challenged by intense signals due to gamma-rays and ultra-relativistic particles from the impact of the 20 GeV proton pulses on the neutron spallation target. A method for analyzing the data taken with Flash Analog to Digital Converters (FADC) was developed to treat these problems in an automated way to provide a reliable background subtraction and a fit routine for identifying fission events even at high energies. The analysis is illustrated at the example of the fission cross-section of U-238 relative to that of U-235 in the energy range from 40 key to 300 MeV. (C) 2010 Elsevier B.V. All rights reserved.oai:cds.cern.ch:13593202010
spellingShingle Nuclear Physics - Experiment
Detectors and Experimental Techniques
Karadimos, D
Stamoulis, K
Papachristodoulou, C
Vlachoudis, V
Assimakopoulos, P
Ioannides, K
Vlastou, R
Karamanis, D
Tsagas, N
Cennini, P
Konovalov, V
Ketlerov, V
Analysis of the FIC detector data at the n_TOF facility
title Analysis of the FIC detector data at the n_TOF facility
title_full Analysis of the FIC detector data at the n_TOF facility
title_fullStr Analysis of the FIC detector data at the n_TOF facility
title_full_unstemmed Analysis of the FIC detector data at the n_TOF facility
title_short Analysis of the FIC detector data at the n_TOF facility
title_sort analysis of the fic detector data at the n_tof facility
topic Nuclear Physics - Experiment
Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.nimb.2010.05.006
http://cds.cern.ch/record/1359320
work_keys_str_mv AT karadimosd analysisoftheficdetectordataatthentoffacility
AT stamoulisk analysisoftheficdetectordataatthentoffacility
AT papachristodoulouc analysisoftheficdetectordataatthentoffacility
AT vlachoudisv analysisoftheficdetectordataatthentoffacility
AT assimakopoulosp analysisoftheficdetectordataatthentoffacility
AT ioannidesk analysisoftheficdetectordataatthentoffacility
AT vlastour analysisoftheficdetectordataatthentoffacility
AT karamanisd analysisoftheficdetectordataatthentoffacility
AT tsagasn analysisoftheficdetectordataatthentoffacility
AT cenninip analysisoftheficdetectordataatthentoffacility
AT konovalovv analysisoftheficdetectordataatthentoffacility
AT ketlerovv analysisoftheficdetectordataatthentoffacility