Development of a Silicon Detector Monitor for the Superconducting Upgrade of the REX-ISOLDE Heavy-Ion Linac at CERN
A silicon detector monitor has been developed and tested in the frame of the beam diagnostics development program for the HIE-ISOLDE superconducting upgrade of the REX-ISOLDE heavy-ion linac at CERN. The monitor is intended for beam energy and timing measurements as well as for phase scanning of the...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1372165 |
Sumario: | A silicon detector monitor has been developed and tested in the frame of the beam diagnostics development program for the HIE-ISOLDE superconducting upgrade of the REX-ISOLDE heavy-ion linac at CERN. The monitor is intended for beam energy and timing measurements as well as for phase scanning of the superconducting cavities. Tests have been performed with a stable ion beam, composed of carbon, oxygen and neon ions accelerated to energies from 300 keV/u to 2.85 MeV/u. The energy measurements performed allowed for beam spectroscopy and ion identification with a resolution of 1.3 % rms. The achieved resolution is suited for cavity phase scanning, which was demonstrated with the REX 7-gap resonator. The time structure of the beam, characterized by a bunch period of 9.87 ns, was measured with a resolution better than 200 ps. This paper describes the results from all these tests as well as providing details of the detector setup. |
---|