Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner
This paper presents the design of the actuator for the fast and high accuracy Wire Scanner system. The actuator consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside the vacuum chamber and the stator installed outside. The fork,...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1375177 |
_version_ | 1780922951681441792 |
---|---|
author | De Freitas, J Dehning, B Emery, J Herranz Alvarez, J F Koujili, M Ramos, D Sapinski, M Ait-Amira, Y Djerdir, A |
author_facet | De Freitas, J Dehning, B Emery, J Herranz Alvarez, J F Koujili, M Ramos, D Sapinski, M Ait-Amira, Y Djerdir, A |
author_sort | De Freitas, J |
collection | CERN |
description | This paper presents the design of the actuator for the fast and high accuracy Wire Scanner system. The actuator consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside the vacuum chamber and the stator installed outside. The fork, permanent magnet rotor and two angular position sensors are mounted on the same axis and located inside the beam vacuum chamber. The system has to resist a bake-out temperature of 200 C and ionizing radiation up to tenths of kGy/year. Maximum wire travelling speed of 20 m/s and a position measurement accuracy of 4 um is required. Therefore, the system must avoid generating vibration and electromagnetic interference. A digital feedback controller will allow maximum flexibility for the loop parameters and feeds the 3-phase linear power driver. The performance of the presented design is investigated through simulations and experimental tests. |
id | cern-1375177 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-13751772022-08-17T13:32:28Zhttp://cds.cern.ch/record/1375177engDe Freitas, JDehning, BEmery, JHerranz Alvarez, J FKoujili, MRamos, DSapinski, MAit-Amira, YDjerdir, ATest Measurements of a 20 ms-1 Carbon Wire Beam ScannerAccelerators and Storage RingsThis paper presents the design of the actuator for the fast and high accuracy Wire Scanner system. The actuator consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside the vacuum chamber and the stator installed outside. The fork, permanent magnet rotor and two angular position sensors are mounted on the same axis and located inside the beam vacuum chamber. The system has to resist a bake-out temperature of 200 C and ionizing radiation up to tenths of kGy/year. Maximum wire travelling speed of 20 m/s and a position measurement accuracy of 4 um is required. Therefore, the system must avoid generating vibration and electromagnetic interference. A digital feedback controller will allow maximum flexibility for the loop parameters and feeds the 3-phase linear power driver. The performance of the presented design is investigated through simulations and experimental tests.CERN-BE-2011-029oai:cds.cern.ch:13751772011-05-01 |
spellingShingle | Accelerators and Storage Rings De Freitas, J Dehning, B Emery, J Herranz Alvarez, J F Koujili, M Ramos, D Sapinski, M Ait-Amira, Y Djerdir, A Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner |
title | Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner |
title_full | Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner |
title_fullStr | Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner |
title_full_unstemmed | Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner |
title_short | Test Measurements of a 20 ms-1 Carbon Wire Beam Scanner |
title_sort | test measurements of a 20 ms-1 carbon wire beam scanner |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1375177 |
work_keys_str_mv | AT defreitasj testmeasurementsofa20ms1carbonwirebeamscanner AT dehningb testmeasurementsofa20ms1carbonwirebeamscanner AT emeryj testmeasurementsofa20ms1carbonwirebeamscanner AT herranzalvarezjf testmeasurementsofa20ms1carbonwirebeamscanner AT koujilim testmeasurementsofa20ms1carbonwirebeamscanner AT ramosd testmeasurementsofa20ms1carbonwirebeamscanner AT sapinskim testmeasurementsofa20ms1carbonwirebeamscanner AT aitamiray testmeasurementsofa20ms1carbonwirebeamscanner AT djerdira testmeasurementsofa20ms1carbonwirebeamscanner |