Cargando…

Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7

At the LHC various underground areas are partly equipped with commercial electronic devices not specifically designed to be radiation tolerant. A major concern is therefore radiation induced failures in particular due to Single Event Upsets (SEU). To ensure safe and acceptable operation of the LHC e...

Descripción completa

Detalles Bibliográficos
Autores principales: ROEED, K, BOCCONE, V, BRUGGER, M, CALVIANI, M, CERUTTI, F, CHIN, P W, CHRISTOV, A, FERRARI, A, KRAMER, D, KWEE, R E, LEBBOS, E, LECHNER, A, LOSITO, R, MALA, P, MEREGHETTI, A, NOWAK, E M, SINUELA PASTOR, D, SPIEZIA, G, THORNTON, A, VERSACI, R, VLACHOUDIS, V, WEISS, C
Lenguaje:eng
Publicado: 2011
Materias:
Acceso en línea:http://cds.cern.ch/record/1376127
_version_ 1780922964258062336
author ROEED, K
BOCCONE, V
BRUGGER, M
CALVIANI, M
CERUTTI, F
CHIN, P W
CHRISTOV, A
FERRARI, A
KRAMER, D
KWEE, R E
LEBBOS, E
LECHNER, A
LOSITO, R
MALA, P
MEREGHETTI, A
NOWAK, E M
SINUELA PASTOR, D
SPIEZIA, G
THORNTON, A
VERSACI, R
VLACHOUDIS, V
WEISS, C
author_facet ROEED, K
BOCCONE, V
BRUGGER, M
CALVIANI, M
CERUTTI, F
CHIN, P W
CHRISTOV, A
FERRARI, A
KRAMER, D
KWEE, R E
LEBBOS, E
LECHNER, A
LOSITO, R
MALA, P
MEREGHETTI, A
NOWAK, E M
SINUELA PASTOR, D
SPIEZIA, G
THORNTON, A
VERSACI, R
VLACHOUDIS, V
WEISS, C
author_sort ROEED, K
collection CERN
description At the LHC various underground areas are partly equipped with commercial electronic devices not specifically designed to be radiation tolerant. A major concern is therefore radiation induced failures in particular due to Single Event Upsets (SEU). To ensure safe and acceptable operation of the LHC electronics a combination of both FLUKA Monte Carlo simulations and dedicated online monitoring is applied to determine the expected radiation levels in critical areas. The LHC Radiation Monitor (RadMon) which is used for this purpose has already been extensively calibrated for its radiation response in various irradiation facilities. It is nevertheless of high importance to also provide a real LHC application benchmark to validate the approach of combined simulations and montoring to correctly measure and predict radiation levels. This report therefore presents a comparison between FLUKA Monte Carlo simulations and measurements results using the RadMon in the LHC collimation region IR7. The work is carried out within the frame work of the R2E project.
id cern-1376127
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2011
record_format invenio
spelling cern-13761272019-09-30T06:29:59Zhttp://cds.cern.ch/record/1376127engROEED, KBOCCONE, VBRUGGER, MCALVIANI, MCERUTTI, FCHIN, P WCHRISTOV, AFERRARI, AKRAMER, DKWEE, R ELEBBOS, ELECHNER, ALOSITO, RMALA, PMEREGHETTI, ANOWAK, E MSINUELA PASTOR, DSPIEZIA, GTHORNTON, AVERSACI, RVLACHOUDIS, VWEISS, CApplication benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7Accelerators and Storage RingsAt the LHC various underground areas are partly equipped with commercial electronic devices not specifically designed to be radiation tolerant. A major concern is therefore radiation induced failures in particular due to Single Event Upsets (SEU). To ensure safe and acceptable operation of the LHC electronics a combination of both FLUKA Monte Carlo simulations and dedicated online monitoring is applied to determine the expected radiation levels in critical areas. The LHC Radiation Monitor (RadMon) which is used for this purpose has already been extensively calibrated for its radiation response in various irradiation facilities. It is nevertheless of high importance to also provide a real LHC application benchmark to validate the approach of combined simulations and montoring to correctly measure and predict radiation levels. This report therefore presents a comparison between FLUKA Monte Carlo simulations and measurements results using the RadMon in the LHC collimation region IR7. The work is carried out within the frame work of the R2E project.CERN-ATS-Note-2011-068 TECHoai:cds.cern.ch:13761272011-08-19
spellingShingle Accelerators and Storage Rings
ROEED, K
BOCCONE, V
BRUGGER, M
CALVIANI, M
CERUTTI, F
CHIN, P W
CHRISTOV, A
FERRARI, A
KRAMER, D
KWEE, R E
LEBBOS, E
LECHNER, A
LOSITO, R
MALA, P
MEREGHETTI, A
NOWAK, E M
SINUELA PASTOR, D
SPIEZIA, G
THORNTON, A
VERSACI, R
VLACHOUDIS, V
WEISS, C
Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7
title Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7
title_full Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7
title_fullStr Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7
title_full_unstemmed Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7
title_short Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7
title_sort application benchmark and comparison of the lhc radiation monitor and fluka monte carlo simulations in ir7
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/1376127
work_keys_str_mv AT roeedk applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT bocconev applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT bruggerm applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT calvianim applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT ceruttif applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT chinpw applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT christova applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT ferraria applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT kramerd applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT kweere applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT lebbose applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT lechnera applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT lositor applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT malap applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT mereghettia applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT nowakem applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT sinuelapastord applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT spieziag applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT thorntona applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT versacir applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT vlachoudisv applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7
AT weissc applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7