Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7
At the LHC various underground areas are partly equipped with commercial electronic devices not specifically designed to be radiation tolerant. A major concern is therefore radiation induced failures in particular due to Single Event Upsets (SEU). To ensure safe and acceptable operation of the LHC e...
Autores principales: | , , , , , , , , , , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2011
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/1376127 |
_version_ | 1780922964258062336 |
---|---|
author | ROEED, K BOCCONE, V BRUGGER, M CALVIANI, M CERUTTI, F CHIN, P W CHRISTOV, A FERRARI, A KRAMER, D KWEE, R E LEBBOS, E LECHNER, A LOSITO, R MALA, P MEREGHETTI, A NOWAK, E M SINUELA PASTOR, D SPIEZIA, G THORNTON, A VERSACI, R VLACHOUDIS, V WEISS, C |
author_facet | ROEED, K BOCCONE, V BRUGGER, M CALVIANI, M CERUTTI, F CHIN, P W CHRISTOV, A FERRARI, A KRAMER, D KWEE, R E LEBBOS, E LECHNER, A LOSITO, R MALA, P MEREGHETTI, A NOWAK, E M SINUELA PASTOR, D SPIEZIA, G THORNTON, A VERSACI, R VLACHOUDIS, V WEISS, C |
author_sort | ROEED, K |
collection | CERN |
description | At the LHC various underground areas are partly equipped with commercial electronic devices not specifically designed to be radiation tolerant. A major concern is therefore radiation induced failures in particular due to Single Event Upsets (SEU). To ensure safe and acceptable operation of the LHC electronics a combination of both FLUKA Monte Carlo simulations and dedicated online monitoring is applied to determine the expected radiation levels in critical areas. The LHC Radiation Monitor (RadMon) which is used for this purpose has already been extensively calibrated for its radiation response in various irradiation facilities. It is nevertheless of high importance to also provide a real LHC application benchmark to validate the approach of combined simulations and montoring to correctly measure and predict radiation levels. This report therefore presents a comparison between FLUKA Monte Carlo simulations and measurements results using the RadMon in the LHC collimation region IR7. The work is carried out within the frame work of the R2E project. |
id | cern-1376127 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2011 |
record_format | invenio |
spelling | cern-13761272019-09-30T06:29:59Zhttp://cds.cern.ch/record/1376127engROEED, KBOCCONE, VBRUGGER, MCALVIANI, MCERUTTI, FCHIN, P WCHRISTOV, AFERRARI, AKRAMER, DKWEE, R ELEBBOS, ELECHNER, ALOSITO, RMALA, PMEREGHETTI, ANOWAK, E MSINUELA PASTOR, DSPIEZIA, GTHORNTON, AVERSACI, RVLACHOUDIS, VWEISS, CApplication benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7Accelerators and Storage RingsAt the LHC various underground areas are partly equipped with commercial electronic devices not specifically designed to be radiation tolerant. A major concern is therefore radiation induced failures in particular due to Single Event Upsets (SEU). To ensure safe and acceptable operation of the LHC electronics a combination of both FLUKA Monte Carlo simulations and dedicated online monitoring is applied to determine the expected radiation levels in critical areas. The LHC Radiation Monitor (RadMon) which is used for this purpose has already been extensively calibrated for its radiation response in various irradiation facilities. It is nevertheless of high importance to also provide a real LHC application benchmark to validate the approach of combined simulations and montoring to correctly measure and predict radiation levels. This report therefore presents a comparison between FLUKA Monte Carlo simulations and measurements results using the RadMon in the LHC collimation region IR7. The work is carried out within the frame work of the R2E project.CERN-ATS-Note-2011-068 TECHoai:cds.cern.ch:13761272011-08-19 |
spellingShingle | Accelerators and Storage Rings ROEED, K BOCCONE, V BRUGGER, M CALVIANI, M CERUTTI, F CHIN, P W CHRISTOV, A FERRARI, A KRAMER, D KWEE, R E LEBBOS, E LECHNER, A LOSITO, R MALA, P MEREGHETTI, A NOWAK, E M SINUELA PASTOR, D SPIEZIA, G THORNTON, A VERSACI, R VLACHOUDIS, V WEISS, C Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7 |
title | Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7 |
title_full | Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7 |
title_fullStr | Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7 |
title_full_unstemmed | Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7 |
title_short | Application benchmark and comparison of the LHC Radiation Monitor and FLUKA Monte Carlo simulations in IR7 |
title_sort | application benchmark and comparison of the lhc radiation monitor and fluka monte carlo simulations in ir7 |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/1376127 |
work_keys_str_mv | AT roeedk applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT bocconev applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT bruggerm applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT calvianim applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT ceruttif applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT chinpw applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT christova applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT ferraria applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT kramerd applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT kweere applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT lebbose applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT lechnera applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT lositor applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT malap applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT mereghettia applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT nowakem applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT sinuelapastord applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT spieziag applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT thorntona applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT versacir applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT vlachoudisv applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 AT weissc applicationbenchmarkandcomparisonofthelhcradiationmonitorandflukamontecarlosimulationsinir7 |